155 results found.
Year: 2019, Volume: 19, Number: 4
... transformer with turns ratio N=NS/NP and leakage source converter (QZSC) has been presented recently with inductances Lk1 and Lk2. In addition, the coupling coefficient many key advantages, such as having low voltage stress on is expressed by =L m /( L m+ L k1). The ...
Terms matched: 1 - Score: 6 - 1,060k
Year: 2019, Volume: 19, Number: 4
... 1 Abstract €” A solution strategy is presented using a five- A match for real load at three independent frequencies using section transmission line impedance transformer aiming for stubbed coupling line was suggested by Wang et al. [2]. multiple band matching network circuits. In this paper, the Another three band matching technique using ...
Terms matched: 1 - Score: 7 - 745k
Year: 2020, Volume: 20, Number: 2
... . pp. 456-462, 2019. doi:10.1049/iet-epa.2018.5336 doi:10.1109/63.892817 [5] D. Panda, V. Ramanarayanan, "Mutual coupling and its effect on [20] E. Mese, D. Torrey, "An approach for sensorless position estimation steady-state performance and position estimation of even ...
Terms matched: 1 - Score: 3 - 1,647k
Year: 2020, Volume: 20, Number: 2
... chosen were right Polarizable electrodes lack the current flow path and, and left upper arm and right abdomen. The upper arm instead, they work as a capacitive coupling between the positions offer an advantageous stretch of the shirt to conductive material and skin [9]. increase pressure on the electrode-skin contact, in order to ...
Terms matched: 1 - Score: 6 - 1,340k
Year: 2020, Volume: 20, Number: 1
... and capacitances. Typical core and winding structure of a transformer can be seen as a complex electrical network of resistances R, self-inductances L, ground capacitances Cg, coupling or mutual inductances Lm, capacitance between windings Cw and series capacitances Cs as shown in Fig. 2. Figure 1. The principle process of FRA measurement ...
Terms matched: 1 - Score: 3 - 625k
Year: 2020, Volume: 20, Number: 1
... iron core, the coils so that no additional AC source is needed. The turn first virtual gap with the smallest area, and second virtual number of the coupling coil Nk is 5% of the total turn gap, respectively. In the actual MCI production process, the number of the main coil attached to each ...
Terms matched: 1 - Score: 15 - 766k
Year: 2019, Volume: 19, Number: 3
... Systems, vol. 5, no. 3, pp. 507-518, 2014. Finally, a strong recommendation can be given about doi:10.1007/s12667-013-0101-5 coupling the proposed power curve modeling framework [18] C. Carrillo, A. F. Obando-Montaño, J. Cidrás, E. Díaz-Dorado, with an ...
Terms matched: 1 - Score: 1 - 748k
Year: 2019, Volume: 19, Number: 3
... is to not packets from sources to destinations according to the breaking the principles of SDN such as centralization OpenFlow protocol and examine these packets to control and monitoring and decoupling controller and data countermeasure different attacks. The two behaviors planes. can be executed in both parallel and pipeline models to Among the others, OpenFlow [10 ...
Terms matched: 1 - Score: 6 - 672k
Year: 2019, Volume: 19, Number: 2
... extensive tests under various working current harmonics in the grid, overheating the instruments, conditions to validate the usefulness of the suggested voltage distortion at the point of common coupling, reduced control. power factor (PF), and minimized efficiency [6] -[ 7]. Compared to the previous state-of-the-art works, the ...
Terms matched: 1 - Score: 3 - 1,610k
Year: 2019, Volume: 19, Number: 2
... AHMED Department of Electronic Engineering, NED University of Engineering and Technology, Karachi, Pakistan sundus@neduet.edu.pk 1 Abstract €” Keeping in consideration the expected need of exploiting decoupling of uplink and downlink connectivity node densification of heterogeneous cellular networks in near for User Equipment (UE), termed as Downlink Uplink future, it is imperative ...
Terms matched: 1 - Score: 14 - 1,223k