148 results found.
Year: 2016, Volume: 16, Number: 1
... the network. Also we will current distribution in effectively grounded power network. treat both cases: uniform, respectively non-uniform spans This method did not include the mutual coupling between lengths and towers impedances. Therefore, the new the ground wire and the faulted phase. In Endrenyi's [3] significant contributions of this work comparing ...
Terms matched: 1 - Score: 20 - 1,140k
Year: 2016, Volume: 16, Number: 2
... goals single phase AC voltage is chopped to buck it at the output. for electrical sources and consumers. In this paper a new No filter stage and no coupling transformer are used, so transformerless single-phase AC voltage regulator based on harmonic level is too high. In the studies given by [6] -[ 10 ...
Terms matched: 1 - Score: 19 - 1,363k
Year: 2012, Volume: 12, Number: 1
... of active power flow supplying the dc voltages to H-bridge inverters and a into/out of the D-STATCOM. If V i lags V s, a small amount coupling inductance with internal resistance (L s+ R s) of active power flows into D-STATCOM and dc-link connecting to ac grid the inverter. capacitor voltage increases ...
Terms matched: 1 - Score: 19 - 994k
Year: 2017, Volume: 17, Number: 1
... period, the system response is sensitive to parameters made AC motors possess torque-generating capability like variation, noise, and the tracking error cannot be controlled DC ones by decoupling the torque and flux control variables directly. Thus, it is essential to abbreviate the period of the of an IPMSM. Although many control strategies have been ...
Terms matched: 1 - Score: 16 - 1,332k
Year: 2021, Volume: 21, Number: 3
... , one control loop for all modules may not reach a of the converter, the deduction of controller parameters and well-balanced input stage and the article presents a the decoupling method, and the simulation model are presented in detail. Simulations show how the system works and interacts decoupling method for a 3 modules system in ISOP with ...
Terms matched: 1 - Score: 15 - 2,068k
Year: 2020, Volume: 20, Number: 1
... iron core, the coils so that no additional AC source is needed. The turn first virtual gap with the smallest area, and second virtual number of the coupling coil Nk is 5% of the total turn gap, respectively. In the actual MCI production process, the number of the main coil attached to each ...
Terms matched: 1 - Score: 15 - 766k
Year: 2019, Volume: 19, Number: 2
... AHMED Department of Electronic Engineering, NED University of Engineering and Technology, Karachi, Pakistan sundus@neduet.edu.pk 1 Abstract €” Keeping in consideration the expected need of exploiting decoupling of uplink and downlink connectivity node densification of heterogeneous cellular networks in near for User Equipment (UE), termed as Downlink Uplink future, it is imperative ...
Terms matched: 1 - Score: 14 - 1,223k
Year: 2015, Volume: 15, Number: 3
... is ‚2x ‚x ‚2 x € € T €0 (5) connected to an AC source, V D. Through the magnetic ‚t 2 ‚t ‚y 2 coupling, the energy transfer from the driving coil to the The solution presented in the below equation, will represent wire is made. The wire's equivalent circuit is ...
Terms matched: 1 - Score: 14 - 1,220k
Year: 2021, Volume: 21, Number: 2
... dynamics. Indeed, chaotic systems on pseudo-chaotic number generators (PCNGs) that are deterministic, it produces signals with characteristics integrate discrete chaotic maps and use the weak coupling that are very similar to random signals, and are highly and switching technique. Dridi et al. [8 ], implemented on sensitive to the initial ...
Terms matched: 1 - Score: 13 - 1,419k
Year: 2013, Volume: 13, Number: 1
... active power filter (SAPF) injects a controlled consists of a full bridge VSI with a capacitor on the DC side, compensating current in the point of common coupling which is connected to the PCC through a coupling inductor (PCC) and needs to be sized only for the compensating in order to attenuate the high switching ...
Terms matched: 1 - Score: 13 - 826k