156 results found.
Year: 2019, Volume: 19, Number: 4
... transformer with turns ratio N=NS/NP and leakage source converter (QZSC) has been presented recently with inductances Lk1 and Lk2. In addition, the coupling coefficient many key advantages, such as having low voltage stress on is expressed by =L m /( L m+ L k1). The ...
Terms matched: 1 - Score: 6 - 1,060k
Year: 2018, Volume: 18, Number: 1
... the next section. The proposed Mode-I: When there is no AC local load demand at the control system uses d-axis current for active power control Point of Common Coupling (PCC), whatever the electric and q-axis current for grid voltage support control. power generated by PV module is completely fed into the main AC grid ...
Terms matched: 1 - Score: 6 - 1,348k
Year: 2022, Volume: 22, Number: 3
... € 0.25t (6) and grid fault current are 90 out of phase with voltage at As stated before, the coordination between fuse and the point of common coupling (PCC) [32]. Therefore, the recloser is preserved as long as ”t 1 ‚ ”t 2 which based on IBDG current under fault conditions ...
Terms matched: 1 - Score: 6 - 1,247k
Year: 2020, Volume: 20, Number: 2
... chosen were right Polarizable electrodes lack the current flow path and, and left upper arm and right abdomen. The upper arm instead, they work as a capacitive coupling between the positions offer an advantageous stretch of the shirt to conductive material and skin [9]. increase pressure on the electrode-skin contact, in order to ...
Terms matched: 1 - Score: 6 - 1,340k
Year: 2014, Volume: 14, Number: 3
... (DYN);- Magtrol brake controller DSP-6001 (CONTR) As it had been expected (Fig. 6, 7), there are commutation- Motor coupling system (CS); over-voltages in the range of about 50% from supply- Motor fixing system (Fig. 4); amplitude, but over-voltages ...
Terms matched: 1 - Score: 6 - 956k
Manuscript template V16/20190503 - Do not alter
... two inputs and j Ts/ 2 outputs with order of 6. The coupled nature of the model 1 € e € sTs € sTs requires for designing a decoupling controller and the G zoh( s) € ‚ Ts e 2 (18) easiest way to design it is to use dynamic inversion. s However ...
Terms matched: 1 - Score: 6 - 2,927k
Year: 2013, Volume: 13, Number: 3
... . This shows that an optimal value for outer air gap thickness can also be found. As for the inner air gap concerns, its increasing lowers the magnetic coupling between rotor and stator and has no Figure 2. Quarter of 2D motor geometry with detail of drag-cup rotor and benefits on motor efficiency, so it is ...
Terms matched: 1 - Score: 6 - 876k
Year: 2013, Volume: 13, Number: 2
... an accurate mechanical power measurement, the test bench is fitted with speed and torque transducers. Due to the torque transducer presence on the common shaft, three elastic couplings are required. As generator, a 4kW/1500rpm series induction motor is employed. Its nameplate power is the mechanical shaft power, thus, in generator ...
Terms matched: 1 - Score: 6 - 877k
Year: 2012, Volume: 12, Number: 3
... (36) € ‚ ‚: €H ‚ (44) ‚t € €0, T € € 0: €H € € T T* where the coupling is through the current density J. and €t ‚ (45) are the electric and thermal conductivities, c and are the where T‚ ...
Terms matched: 1 - Score: 5 - 1,339k
Year: 2017, Volume: 17, Number: 3
... ƒ axis can be controlled independently, by transforming the 1 1 ƒ € € ƒ ƒ”x4 ƒ attraction forces of the electro-magnets assuming that the ƒb b b bƒ coupling effect is negligible. By controlling each DoF, each In the same manner, a current transform matrix is defined gap clearance can be controlled using the transformation ...
Terms matched: 1 - Score: 5 - 2,636k