155 results found.
Year: 2015, Volume: 15, Number: 3
... generator and the EUT's impedance to which the surge generator is connected. Surge is applied without connection of observed system to power network, ie. with surge direct coupling between Figure 1. Model of the observed system. lines to neutral [21]. Values of amplitudes of voltage and Equipment under test (EUT) ...
Terms matched: 1 - Score: 3 - 1,482k
Year: 2015, Volume: 15, Number: 3
... negative correlation with considered worthy if it is confirmed by all indices. In Table RAND is expected. Such behaviour for the majority of III we present all possible couplings of distance metrics used datasets was found for HEOM. Other distances only for to calculate internal measures. The best results (triple some datasets were highly negatively ...
Terms matched: 1 - Score: 3 - 1,251k
Year: 2015, Volume: 15, Number: 3
... the consumer. In most cases, the consumer of electricity is responsible for altering the power quality in the II. STRATEGIES FOR COMMAND AND CONTROL point of common coupling (PCC). Regarding power quality issues, harmonics have a significant importance, because The aim of active filters control is to generate signals for many of ...
Terms matched: 1 - Score: 3 - 1,263k
Year: 2015, Volume: 15, Number: 3
... 1 represents one phase of a the equivalent resistor-inductor circuit of the SRM and do locked-rotor SRM supplied from the asymmetric power not include the leakage fluxes, the mutual coupling between converter- the type of converter predominantly used in the phases or the iron losses [2, 4, 6, 7, 17, 18] ...
Terms matched: 1 - Score: 9 - 1,201k
Year: 2015, Volume: 15, Number: 3
... is ‚2x ‚x ‚2 x € € T €0 (5) connected to an AC source, V D. Through the magnetic ‚t 2 ‚t ‚y 2 coupling, the energy transfer from the driving coil to the The solution presented in the below equation, will represent wire is made. The wire's equivalent circuit is ...
Terms matched: 1 - Score: 14 - 1,220k
Year: 2015, Volume: 15, Number: 3
... Fromen, M. Glinkowski, et al., "Mathematical protection based on the differential current gradient," Electric Power Models for Current, Voltage, and Coupling Capacitor Voltage Systems Research, vol. 111, pp. 78 €“ 84, 2014. [Online]. Available: Transformers," IEEE Transactions on ...
Terms matched: 1 - Score: 3 - 1,566k
Year: 2015, Volume: 15, Number: 3
... on the detection, minimization of the capacitive leakage current, proposed converter topology, a PSpice simulation model and a 600 W converter prototype were developed. Both simulation decoupling of PV panels from the grid, etc. Due to its good and experimental results show successful operation of the properties, a 3-level neutral-point-clamped (NPC) ...
Terms matched: 1 - Score: 3 - 2,048k
Year: 2015, Volume: 15, Number: 3
... that current the effect of interaction among concurrently running approaches to cloud computing suffer from their own queries. This approach relies on experiment-driven advantages: infrastructure sharing and the decoupling of performance modelling, and a workload simulator that uses applications from providers of the service. the performance models to simulate the execution of a A. Mumtaz ...
Terms matched: 1 - Score: 3 - 1,408k
Year: 2015, Volume: 15, Number: 3
... , power signal, the first step consists in applying a modal 19 Advances in Electrical and Computer Engineering Volume 15, Number 3, 2015 transformation to eliminate mutual coupling between Under these conditions, the traveling wave pulses travel phases. Clarke transformation was used throughout this from the fault to R 1 and arrive at the local ...
Terms matched: 1 - Score: 3 - 1,306k
Year: 2015, Volume: 15, Number: 3
... the linear induction motor drive applications [4-7]. The main LIM, which can be directly used in vector control idea behind IFOC in an LIM is the decoupling of the flux applications, has become an indispensable challenge for the and the torque. The flux orientation can be achieved by researches. The simplest method to ...
Terms matched: 1 - Score: 3 - 1,163k