266 results found containing all search terms.
Year: 2014, Volume: 14, Number: 4
... 16-QAM modulation better protects the bit ai than the bit bi. size of a data block at the turbo encoder input is of 2‚752 7 bits. We considered ... the frame error rate from a value FERnc, in the case of an uncoded transmission, to a value FERTC, in the case of a turbo coded transmission ...
Terms matched: 2 - Score: 16 - 684k
Year: 2014, Volume: 14, Number: 3
... ~ R (), the real-time Bus-3 0.0984 0.0896 Bus-4 0.0641 0.0614 measurement data of Bus negative sequence voltage have Bus-5 0.0602 0.0631 been obtained, see Table ... the interference in the process of power The purpose of network topology identification of power transmission is everywhere. Especially for WAMS system, system is to carry on bus ...
Terms matched: 2 - Score: 16 - 739k
Year: 2015, Volume: 15, Number: 3
... being analyzed with construction body [19]. In this way, a complete data set both circuits magnetically coupled. about the construction behavior through a desired time ... ] D.C. Yates, A.S. Holmes, A.J. Burdett, "Optimal transmission wire. The two distinct circuits are magnetically coupled. The frequency for ultralow-power ...
Terms matched: 2 - Score: 16 - 1,220k
Year: 2010, Volume: 10, Issue: 3
... current components performance evalution using recorders field High impedance Connection point: wet 1.0023 1 data", IEEE Transactions on Power Delivery, vol. 3, no. ... fault detection", in Proc. of 1994 IEEE Int. Conf. on Transmission and fault sand at bus 4 High impedance Connection point: distribution, pp ...
Terms matched: 2 - Score: 16 - 528k
Year: 2018, Volume: 18, Number: 2
... the setup is used for investigating discharge signals of pressboard fractal figure contain complete figure data without any loss. samples under different electrical stresses. This paper proposes In ... . Zhao, C. Li, H. Wu, "Interface charge polarity transmission system) for proposed test procedure. In effect based analysis model for electric ...
Terms matched: 2 - Score: 16 - 1,298k
Year: 2009, Volume: 9, Issue: 2
... for solving an electromagnetic interference problem h [m] 1 2 2 The input data for all this type of interference problems w1 0.693 0.441 0.339 are (see ... of a soil structure composed of two layers with induced in layered soil by HV transmission lines in normal different resistivity, both horizontally, in respect with the conditions ...
Terms matched: 2 - Score: 16 - 608k
Year: 2019, Volume: 19, Number: 2
... loads such as communication buildings reliable and cost-effective sources to meet big scale energy and data centers. The increase in the use of DC voltage demand until the last ... compensation configurations are mostly preferred in distribution and performance more than the conventional configuration. transmission electrical grids. Power quality disturbances must be properly classified to ensure the reliability ...
Terms matched: 2 - Score: 15 - 1,822k
Year: 2011, Volume: 11, Number: 2
... , RD, DSV and SC) affect the TFs and modify them. more data about DSV and find out precise information For example, the measured TFs ( ... index played its role only to specify the level of equipments in the electrical power transmission and AD or RD and does not specify the type of fault. In ...
Terms matched: 2 - Score: 13 - 823k
Year: 2022, Volume: 22, Number: 3
... . In this case, the percentage increase is 18% while using The load data and distribution line information can be found the proposed method in scenario 3, ... , pp. 822-836, 2018. distributed energy resources," IET Generation, Transmission& doi:10.1016/j.energy.2018.08.022 Distribution, vol. 10, pp. ...
Terms matched: 2 - Score: 13 - 1,247k
Year: 2009, Volume: 9, Issue: 2
... .0 .0 .0 .0 .0 .0 .0 .0 .0 .0 .1 .1 .1 .1 02 Data Figure 8. Quality control chart of lead. Figure 5. The DRC ... results in improved ion The DRC is located between the ion optics and the mass transmission and sensitivity). analyzer quadrupole. It consists of a quadrupole placed inside ...
Terms matched: 2 - Score: 13 - 635k