255 results found.
Year: 2015, Volume: 15, Number: 2
... changed to 1 m. The Appendix A. The functions H and E are the same. A ground grid deep was 0.1 and 0.9 meters. For a fault current of 100 rod of 3 m length and 8 mm radius was considered, with the A, equipotential lines in the vertical plane that crosses the top ...
Terms matched: 1 - Score: 3 - 877k
Year: 2015, Volume: 15, Number: 2
... R. B. B. Jose, "A Power Electronic Controller for PV-tied Grid-connected System with Single able to limit the dc-side current in the event that a fault Parameter Sensing for Mppt Using Boost Converter and Line- occurs in the grid. However, in the future work, it is commutated Inverter," in ...
Terms matched: 1 - Score: 3 - 894k
Year: 2017, Volume: 17, Number: 1
... to supply [13] B. Peng, I-Y Chen, "IC HTOL Stress Condition Optimization", variations determines the precision the hysteresis width can Defect and Fault Tolerance in VLSI Systems, 19th IEEE International be set by. Four possible designs were considered for this Symposium, 2004, pp 272-279, doi: 10.1109 ...
Terms matched: 1 - Score: 3 - 1,337k
Year: 2017, Volume: 17, Number: 1
... Chow, H.J. Trussell, "Fuzzy inference systems Networking vol. 9, issue 3, pp. 191-204, 2012. implemented on neural architectures for motor fault detection and doi:10.1016/j.osn.2012.02.001 diagnosis", IEEE Trans. Industrial Electronics, vol. 46, pp. 1069- [4] H. ...
Terms matched: 1 - Score: 3 - 1,216k
Year: 2013, Volume: 13, Number: 2
... of cryptographic algorithms [17]. Further then the transmitter can send up to 50 blocks per second. on, some solutions incorporate a very complicated With a default block size of 512 bytes, the transfer rate is authentication system that uses a time synchronization bounded to 25 kB/s [1 ][ 10] ...
Terms matched: 1 - Score: 3 - 908k
Year: 2012, Volume: 12, Number: 1
... the Translate button if the input Figure 1. A sample web application GUI text area is empty or any of the languages is not selected. Even if a faulty interaction occurs, manual operation allows The rest of the paper is organized as follows. In Section 2, the user to correct herself through multiple trial-and-error we ...
Terms matched: 1 - Score: 3 - 567k
Year: 2010, Volume: 10, Issue: 4
... or synchronous machines due to lack of windings on the stator or translator structure, Index Terms — Linear switched reluctance motor, finite easier manufacturing and maintenance, good fault element analysis, force ripple, FFT tolerance capability [1]. LSRMs are classified as (a) longitudinal flux (b) transverse flux. This ...
Terms matched: 1 - Score: 3 - 1,979k
Year: 2019, Volume: 19, Number: 2
... output voltage of RESs. The electrical and have no need for utility energy except in emergencies characteristics of RESs power should be compatible with such as overloading and system faults. In self-sufficient distribution systems in terms of frequency, phase angle and microgrids, utility grid is utilized as a backup system, and voltage amplitude. Otherwise ...
Terms matched: 1 - Score: 3 - 1,822k
Year: 2019, Volume: 19, Number: 2
... O. Estima, A. J. M. Cardoso, "A New Algorithm for Real-Time with Bridgeless PFC and Four Switch Inverter," International Multiple Open-Circuit Fault Diagnosis IN Voltage-Fed PWM Motor Conference on Emerging Trends in Communication Control Signal Drives by the Reference Current Errors," IEEE Trans. on Industrial Processing and Computing ...
Terms matched: 1 - Score: 3 - 1,610k
Year: 2019, Volume: 19, Number: 2
... system Index Terms — pattern recognition, memristors, neural thanks to their low power consumption, high density, and network, neural network hardware, speech recognition. fault tolerance [12 – 16]. For example, the filamentary I. INTRODUCTION switching binary 2M synapse, consisting of M+ memristor crossbar array and M ...
Terms matched: 1 - Score: 3 - 1,762k