569 results found.
Year: 2019, Volume: 19, Number: 3
... "BalanceFlow: (pps) (ms) Controller load balancing for OpenFlow networks," in 2012 IEEE ... Available: http://archive.openflow.org/wp/downloads/. [Accessed 16 2017]. November ... this B. HPOFS Architecture mechanism, memory could be overloaded and is the weakness of this approach. LineSwitch ...
Terms matched: 3 - Score: 10 - 672k
Year: 2019, Volume: 19, Number: 2
... simulation results are indicated and performed under different weather and load conditions. discussed in the fifth section. Finally ... sources. However, RESs were not to support sensitive loads such as communication buildings reliable and cost-effective sources to ... and the speed of global can be changed under variable loading conditions to warming [3]. Not only ...
Terms matched: 4 - Score: 116 - 1,822k
Year: 2019, Volume: 19, Number: 2
... determine recloser power distribution systems. A performance analysis of load cluster priorities, it is proposed to consider statistical ... the maximum of average number of consumer units. Critical loads are also considered peak currents in the period from ... a.m. to 7 p.m. exceeds the as a decision factor in the cluster choice. current of 600 ...
Terms matched: 3 - Score: 54 - 1,192k
Year: 2019, Volume: 19, Number: 2
... viscous friction, Te and Tl are the motor and load g) The switch gate signal (g) ... the current controllers and the three control signals using The no-load and short-circuit tests are used to obtain the ( ... separately excited DC generator is coupled with the IM for loading tests. Cuk converter consists of a switch, ...
Terms matched: 5 - Score: 46 - 1,610k
Year: 2019, Volume: 19, Number: 2
... The IM are exposed to different applications to identify one and two BRB s in steady state mechanical, magnetic, electrical, and thermal stimulus, with also different load levels. In [7 ], authors use a which frequently could cause failures [1]. From all possible combination of a filter bank and the ...
Terms matched: 1 - Score: 28 - 1,378k
Year: 2019, Volume: 19, Number: 2
... system performance. PSO optimized PID controllers are hybrid MG system during intermittent conditions of load and used in D-FACTS. generation. In addition, a comparative study of ... optimization, particle swarm optimization (PSO) and experimental validation is made using pulsed loads. A grid the PSO with new update mechanism (PSOd) are used ...
Terms matched: 2 - Score: 67 - 1,471k
Year: 2019, Volume: 19, Number: 2
... , switching frequency, and [6] A. Ayed, Tr. Dubois, J. L. Levant, and G. Duchamp, "A New method load capacitance. This dependency is clearly depicted by the for the characterization of electronic components immunity," IEEE measurement results in Fig. 19. Note that the ...
Terms matched: 1 - Score: 5 - 1,450k
Year: 2019, Volume: 19, Number: 2
... are the III. INDUCTION MOTOR DESIGN applied armature voltage and current, ω is the angular rotor A. Theory speed in rad/s, TL is the load torque, Pi and Po are the input and output powers, Pm is the electromechanical power, PCu The field oriented control (FOC) with short circuited ...
Terms matched: 1 - Score: 6 - 1,202k
Year: 2019, Volume: 19, Number: 2
... RDTSC: This is the instruction that returns the scheme. First, the Pin loads the target program (e.g., processor timestamp value, which records the ... . 2, pp. 208-222, 2018. https://tuts4you.com/download.php?view.2028, 2012. [30] Obsidium Software. "Obsidium Software ...
Terms matched: 2 - Score: 5 - 1,283k
Year: 2019, Volume: 19, Number: 2
... causing obtain on-line systems. Different parallel systems disturbance events are present with a considerable portion of architectures as multi-core central processing units (CPU) them because of customer loads [6]. These can cause and graphics processing units (GPU) are present these days harmonic content (due to nonlinear loads), poor power ...
Terms matched: 1 - Score: 10 - 1,585k