Year: 2022, Volume: 22, Number: 1
... through microgrid system configuration and modelling is described the regulation of power unbalance created by load and the in the section 2 including PV and battery modelling together variation of ... , PV cell can be modeled in several ways. The most BESS and AC loads, used as test model, is given on the Fig. frequently used ...
Terms matched: 2 - Score: 115 - 1,928k
Year: 2021, Volume: 21, Number: 4
... , an MMC is obtained quite well as nearly 0.25%. In addition, load voltage topology can be used as the power electronic interface in control is accomplished ... power to both entire control system models are addressed in detail and grid and stand-alone loads [1-5]. Generated energy from the adequate system performance is obtained in ...
Terms matched: 2 - Score: 114 - 2,802k
Year: 2012, Volume: 12, Number: 2
... special interest in low power wind energy battery energy storage system during wind speed and load applications due to their small size and high power density. variations. The ... primary advantage of PMSGs is that they do not require required power for the connected loads can be effectively any external excitation current. A major cost benefit in using ...
Terms matched: 2 - Score: 113 - 995k
Year: 2017, Volume: 17, Number: 1
... bands in loads. The proposed controller parameter-tuning procedure is based on the three-phase back-EMF-type load, which [3-4] that can partially solve this problem. corresponds to ... (VSI) nonidealities and by nonlinear controllers are proposed with adaptive hysteresis bands in loads. The proposed controller parameter-tuning procedure is based on the three-phase back-EMF-type load, ...
Terms matched: 2 - Score: 110 - 1,282k
Year: 2020, Volume: 20, Number: 1
... ensures better dynamic performance for line provide effective power conversion with good operating variations and load variations [11]. Output voltage can be performance. This paper deals ... 150 V) for PID controller. From this figure, it is inferred light loading conditions, the output response has that output voltage is severely affected by sudden ...
Terms matched: 2 - Score: 84 - 787k
Year: 2007, Volume: 7, Issue: 2
... below the average and the cvasipeak Mains filters are tested with a 50Ω source and load values, according to the standard in the frequency range of impedance because most ... kW), installed in the houses of the village, presented since connected electrical loads can present virtually any RF malfunctions, and gave error messages on the interface ...
Terms matched: 2 - Score: 84 - 349k
Year: 2011, Volume: 11, Number: 1
... Electrical and Computer Engineering Volume 11, Number 1, 2011 The Impact of the Load Side Parameters on PC Cluster's Harmonics Emission Vladimir A. KATIĆ1, Saša V ... certain number of PCs in a cluster the THDI=f (NPC) power loads are regulated with several standards or line cease to decrease and becomes constant, ...
Terms matched: 2 - Score: 84 - 851k
Year: 2019, Volume: 19, Number: 4
... Abstract — A solution strategy is presented using a five- A match for real load at three independent frequencies using section transmission line impedance transformer aiming for stubbed coupling ... alternative can be the application of shunt stub matching three distinct frequencies especially for complex loads technique. which is very difficult to attain. As a further contribution, ...
Terms matched: 2 - Score: 83 - 745k
Year: 2020, Volume: 20, Number: 4
... Advances in Electrical and Computer Engineering Volume 20, Number 4, 2020 Multi-objective Environmental-economic Load Dispatch Considering Generator Constraints and Wind Power Using Improved Multi-objective Particle Swarm Optimization Tankut ... employ both functional inertia weight and On the other hand, if the valve point loading effects are functional constriction factor. When selecting the text considered in the fuel ...
Terms matched: 2 - Score: 82 - 1,225k
Year: 2012, Volume: 12, Number: 2
... and Ï„ depend on the So, combustion efficiency increases with rising of bed boiler load (Table I), while the recommended value of the temperature by providing ... its important for decreasing these emissions and increasing the performances are compared at different boiler loads with those combustion efficiency [13]. of a Fuzzy Logic (FL ...