Click to open the HelpDesk interface
AECE - Front page banner

Menu:


FACTS & FIGURES

JCR Impact Factor: 1.221
JCR 5-Year IF: 0.961
SCOPUS CiteScore: 2.5
Issues per year: 4
Current issue: Aug 2021
Next issue: Nov 2021
Avg review time: 92 days


PUBLISHER

Stefan cel Mare
University of Suceava
Faculty of Electrical Engineering and
Computer Science
13, Universitatii Street
Suceava - 720229
ROMANIA

Print ISSN: 1582-7445
Online ISSN: 1844-7600
WorldCat: 643243560
doi: 10.4316/AECE


TRAFFIC STATS

1,749,405 unique visits
580,822 downloads
Since November 1, 2009



Robots online now
PetalBot


SJR SCImago RANK

SCImago Journal & Country Rank




TEXT LINKS

Anycast DNS Hosting






LATEST NEWS

2021-Jun-30
Clarivate Analytics published the InCites Journal Citations Report for 2020. The InCites JCR Impact Factor of Advances in Electrical and Computer Engineering is 1.221 (1.053 without Journal self-cites), and the InCites JCR 5-Year Impact Factor is 0.961.

2021-Jun-06
SCOPUS published the CiteScore for 2020, computed by using an improved methodology, counting the citations received in 2017-2020 and dividing the sum by the number of papers published in the same time frame. The CiteScore of Advances in Electrical and Computer Engineering in 2020 is 2.5, better than all our previous results.

2021-Apr-15
Release of the v3 version of AECE Journal website. We moved to a new server and implemented the latest cryptographic protocols to assure better compatibility with the most recent browsers. Our website accepts now only TLS 1.2 and TLS 1.3 secure connections.

2020-Jun-29
Clarivate Analytics published the InCites Journal Citations Report for 2019. The InCites JCR Impact Factor of Advances in Electrical and Computer Engineering is 1.102 (1.023 without Journal self-cites), and the InCites JCR 5-Year Impact Factor is 0.734.

2020-Jun-11
Starting on the 15th of June 2020 we wiil introduce a new policy for reviewers. Reviewers who provide timely and substantial comments will receive a discount voucher entitling them to an APC reduction. Vouchers (worth of 25 EUR or 50 EUR, depending on the review quality) will be assigned to reviewers after the final decision of the reviewed paper is given. Vouchers issued to specific individuals are not transferable.

Read More »


SEARCH THE JOURNAL CONTENT


Enter one or more keywords to search for.
For exact phrase matching use quotation marks (e.g. "speed controller").
Note that '*' and '?' wildcards are supported.

Search for:

Results per page:

Match: any search words all search words

Search results for: load

511 results found.

52 pages of results.
Sorted by relevance / Sort by date
Year: 2007, Volume: 7, Issue: 1
... way to obtain analyzed quantities numerical values (both in influenced by the rectifier and load circuits characteristics. transient or steady state). MathCAD functions were created To ... without hysteresis loop [8 ,9]. switching mode, RL and RC loaded (with current or voltage rectifiers in secondary winding). Comparisons between experimentally ...
Terms matched: 2  -  Score: 61  -  535k
Year: 2010, Volume: 10, Issue: 3
... to discriminate the HIF current from packet. currents of capacitor switching, line and load switching and non-linear load currents that behave like HIF current. The Model of ... eighty Arc current at each half-cycle during HIF produces high patterns are used for nonlinear loads. frequency components. These components can be used to For discriminating the HIF ...
Terms matched: 2  -  Score: 60  -  528k
Year: 2017, Volume: 17, Number: 1
... have been commonly Regulator (LQR) technique to simultaneously control the tracking trajectory and load torque changes. The quadratic employed in motor drives owing to their easy design ... DSP TMS320C31. The IPMSM is coupled -12 with a separately excited DC generator for loading. The 0 1 2 3 4 5 6 7 IPMSM is supplied by ...
Terms matched: 2  -  Score: 60  -  1,332k
Year: 2011, Volume: 11, Number: 3
... the DFT, cannot be parallel active filter (PAF) is used to compensate load 31 Advances in Electrical and Computer Engineering Volume 11, Number 3, 2011 ... of the signal. The phase-locked loop (PLL) is used for the varying loads in the electric power system is widespread and synchronisation of the algorithm based on ...
Terms matched: 2  -  Score: 59  -  803k
Year: 2010, Volume: 10, Issue: 4
... . interference during system operation: (a) external interference, which refers to load torque oscillations on the II. DESCRIPTION AND MODELING OF THE SYSTEM driving chain ... the role of an active parallel filter (APF) harmonic pollution due to nonlinear loads such as power and is required in order to mitigate the harmonic pollution. ...
Terms matched: 2  -  Score: 51  -  1,152k
Year: 2013, Volume: 13, Number: 3
... is used to determine these parameters and a designer source because its output changes with load current, uses his experiences about the system. This process may temperature, ... can be calculated with: surface. If the output of the PV cell is loaded or short ƒT ƒ 2 ƒ q ƒ— Eg ƒ 1 1 ƒƒ I ...
Terms matched: 2  -  Score: 50  -  764k
Year: 2013, Volume: 13, Number: 1
... the two approaches, namely those based on the Fryze-Buchholz- fundamental components of the load current and generate Depenbrock theory and the generalized instantaneous reactive the compensating currents. ... and increasing use of nonlinear reference currents, attention is directed to the control loops loads in both industrial and domestic electrical systems, the design and digital control implementation ...
Terms matched: 2  -  Score: 50  -  826k
Year: 2014, Volume: 14, Number: 3
... waveform. Given that the supply voltage is has good performances, irrespective of the load nature. The sinusoidal, the most favorable sampling is uniform adequate functioning and ... of the AC-AC boost converter. The circuit functions adequately both for resistive and inductive loads. Digital Object Identifier 10.4316/AECE.2014.03014 107 1582-7445© 2014 AECE Advances in ...
Terms matched: 2  -  Score: 50  -  832k
Year: 2018, Volume: 18, Number: 1
... . This structure improves the response of the proposed VSC under speed reference tracking and load disturbance IM were executed and the electromagnetic parameters were changes. Stability of VSC ... under step speed change using 1DOF of 1.1 kW IM integrated to DC generator for loading control method are illustrated in Fig. 8(a) and Fig. ...
Terms matched: 2  -  Score: 50  -  1,688k
Year: 2018, Volume: 18, Number: 3
... in an iterative process to achieve global optimum. Since in this work latter Economic load dispatch is one of important operation in methodology is implemented an elaborated survey is ... sine components included to represent the valve point problem is addressed as a multi-objective optimization loading effects. The total fuel cost ($ /h) is can be ...
Terms matched: 2  -  Score: 46  -  1,210k
Result Pages: << Previous 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 Next >>


Search took 0.243 seconds


The search engine database includes all papers published after 2007, including titles, author names, abstracts, keywords, full papers text, references and citations. For papers published between 2001 and 2006, please visit the Archive section.


We invite you to try the most frequently used search terms:

system - power - control - fault - network - load - model - frequency - converter - transformer - harmonic - computer - algorithm - cancer - simulation - computer - estimate - optimal control - expert system - electromagnetic - interference - data transmission - neural network - electrocardiogram signal - model - cluster - design - wavelet - antenna - wireless sensor - coupling - robust - noise - signal processing - system identification - translation - nonlinear systems - induction motor - speed controller - shape optimization - fuzzy network - wireless sensor network


Website loading speed and performance optimization powered by: