149 results found.
Year: 2013, Volume: 13, Number: 2
... transmission branch Locational Marginal Price (LMP) differences (inconsistency of (line or transformer) usually constrained by thermal LMPs) that arise at the boundary buses between ... If we look at the Table III, the LMP difference between the From-bus and Transformers 9 Branch Charging (inj) 1345.93 To-bus ends equals the absolute value of ...
Terms matched: 2 - Score: 5 - 717k
Year: 2007, Volume: 7, Issue: 2
... in Electrical and Computer Engineering Volume 7 (14), Number 2 (28), 2007 Controlled Interphase Power Controller (IPC) on the Base of Squashed Transformer Mihail KIORSAK, Leo KALININ, Tudor AMBROS Technical University, 31 August str. 78, MD-2012 Kishinau Institute of Power Engineering, Academy 5 str., ...
Terms matched: 1 - Score: 315 - 1,117k
Year: 2011, Volume: 11, Number: 2
... generating higher or lower where the low frequency PWM pulse is modulating a higher resonant frequency required by the ZVS inverter's intensity radiations, as demanded. The CW commercial transformer. The method presented allows a continuous magnetron (and its conventional power supply) is not control of both power and energy (duty-cycle) at the inverter's ...
Terms matched: 1 - Score: 45 - 759k
Year: 2010, Volume: 10, Issue: 1
... able to supply a high output Digital Object Identifier 10.4316/AECE.2010.01018 100 Advances in Electrical and Computer Engineering Volume 10, Number 1, 2010 DC voltage because its transformer has the turns ratio The average current through diode D reflected in the greater than one. The experimental results are useful to primary winding of the transformer Tr ...
Terms matched: 1 - Score: 43 - 536k
Year: 2022, Volume: 22, Number: 1
... D maximum power point MPP. The grid is connected to the where, VPV and VDC are respectively the input and output inverter via a filter and a DY transformer whose secondary voltage. D is the duty cycle value located between 0 and 1. winding (high voltage) is connected to the grid. A filter ...
Terms matched: 1 - Score: 39 - 1,648k
Year: 2015, Volume: 15, Number: 2
... to maximum power tracking via the current sensor, a line-commutated inverter module, a reference current instead of the firing angle. In addition, controller, and step-up transformer, which is shown in power factor can be controlled by changing firing angle of Fig. 3. Moreover, operating principle with switching SCRs. Thus, ...
Terms matched: 1 - Score: 36 - 894k
Year: 2019, Volume: 19, Number: 1
... , is development [6]. presented. The interface is composed of a single-phase active Different power architectures and converter topologies rectifier and a three-phase inverter with output transformer, wherein the Photovoltaic (PV) string is straightly connected to have been proposed to integrate renewable sources and the DC-link, avoiding the use of additional converter ...
Terms matched: 1 - Score: 35 - 1,518k
Year: 2016, Volume: 16, Number: 1
... of producing the non-inverted in which the input ports are isolated from the output port output voltage with reduced ripple current in the output port. using high frequency isolation transformer. The proposed The output voltage has reduced settling time, rise time and converter topology can interface four ports, viz., two PV increased step-up and ...
Terms matched: 1 - Score: 33 - 1,854k
Year: 2020, Volume: 20, Number: 4
... associated to the existence of communication equipment that and charging of plug-in electric vehicles to assess, use the earthing conductor for signal grounding purposes respectively, voltage unbalance and transformer aging. [6 ], which may suffer from disruption of communication Digital Object Identifier 10.4316/AECE.2020.04006 45 1582-7445© 2020 AECE Advances in Electrical and Computer ...
Terms matched: 1 - Score: 22 - 1,302k
Year: 2009, Volume: 9, Issue: 2
... 10 In order to calculate the risk of the load curtailment, the -1 10 maximum generators real power, the load active powers, the Probability transmission lines and transformers rated power and 10 -2 reactance (in pu) and the failure and repair rates of generators, transmission lines and transformers, should be 10 -3 known ...
Terms matched: 1 - Score: 21 - 614k