Click to open the HelpDesk interface
AECE - Front page banner

Menu:


FACTS & FIGURES

JCR Impact Factor: 0.800
JCR 5-Year IF: 1.000
SCOPUS CiteScore: 2.0
Issues per year: 4
Current issue: Feb 2024
Next issue: May 2024
Avg review time: 75 days
Avg accept to publ: 48 days
APC: 300 EUR


PUBLISHER

Stefan cel Mare
University of Suceava
Faculty of Electrical Engineering and
Computer Science
13, Universitatii Street
Suceava - 720229
ROMANIA

Print ISSN: 1582-7445
Online ISSN: 1844-7600
WorldCat: 643243560
doi: 10.4316/AECE


TRAFFIC STATS

2,529,368 unique visits
1,005,674 downloads
Since November 1, 2009



Robots online now
SemanticScholar


SCOPUS CiteScore

SCOPUS CiteScore


SJR SCImago RANK

SCImago Journal & Country Rank




TEXT LINKS

Anycast DNS Hosting
FEATURED ARTICLES

Application of the Voltage Control Technique and MPPT of Stand-alone PV System with Storage, HIVZIEFENDIC, J., VUIC, L., LALE, S., SARIC, M.
Issue 1/2022

AbstractPlus






LATEST NEWS

2023-Jun-28
Clarivate Analytics published the InCites Journal Citations Report for 2022. The InCites JCR Impact Factor of Advances in Electrical and Computer Engineering is 0.800 (0.700 without Journal self-cites), and the InCites JCR 5-Year Impact Factor is 1.000.

2023-Jun-05
SCOPUS published the CiteScore for 2022, computed by using an improved methodology, counting the citations received in 2019-2022 and dividing the sum by the number of papers published in the same time frame. The CiteScore of Advances in Electrical and Computer Engineering for 2022 is 2.0. For "General Computer Science" we rank #134/233 and for "Electrical and Electronic Engineering" we rank #478/738.

2022-Jun-28
Clarivate Analytics published the InCites Journal Citations Report for 2021. The InCites JCR Impact Factor of Advances in Electrical and Computer Engineering is 0.825 (0.722 without Journal self-cites), and the InCites JCR 5-Year Impact Factor is 0.752.

2022-Jun-16
SCOPUS published the CiteScore for 2021, computed by using an improved methodology, counting the citations received in 2018-2021 and dividing the sum by the number of papers published in the same time frame. The CiteScore of Advances in Electrical and Computer Engineering for 2021 is 2.5, the same as for 2020 but better than all our previous results.

2021-Jun-30
Clarivate Analytics published the InCites Journal Citations Report for 2020. The InCites JCR Impact Factor of Advances in Electrical and Computer Engineering is 1.221 (1.053 without Journal self-cites), and the InCites JCR 5-Year Impact Factor is 0.961.

Read More »


SEARCH THE JOURNAL CONTENT


Enter one or more keywords to search for.
For exact phrase matching use quotation marks (e.g. "speed controller").
Note that '*' and '?' wildcards are supported.

Search for:

Results per page:

Match: any search words all search words

Search results for: transformer

158 results found.

16 pages of results.
Sort by relevance / Sorted by date ▼
Year: 2015, Volume: 15, Number: 4
... 1F- vdc Vienna topology (M =1 ), the most popular PWM boost-type PFC concept with three voltage levels. By adding auxiliary Filter/ PWM PWM Transformer/ active power device(s) to 1F-Vienna circuit and through proper Rectifier Inverter Grid modulation strategies, the ripple frequency present in the input (a) ...
Terms matched: 1  -  Score: 3  -  1,193k
Year: 2015, Volume: 15, Number: 4
... excitation systems and Load Positive sequence of Real power, reactive Line governors. The transformer between buses 11 and 12 is buses voltage and current power breaker status modified ... burden; (ii) the novel application of measurement-based Changer (ULTC) of transformers, the operation of Over- clustering approach for voltage stability studies; ( ...
Terms matched: 2  -  Score: 18  -  1,493k
Year: 2015, Volume: 15, Number: 3
... ] B.S. Dupczak, A.J. Perin, M.L. Heldwein, "Space vector modulation http://dx.doi.org/10.1109/TIE.2008.924160 strategy applied to interphase transformers-based five-level current [15] J. Dai, D. Xu, and B. Wu, "A Novel control scheme for current- source inverters, ...
Terms matched: 1  -  Score: 3  -  1,143k
Year: 2015, Volume: 15, Number: 3
... components are (14) and (15) respectively, The main parts of the schematic diagrams are the power supply, consisting in a 230/24 V transformer, the nonlinear load fed by the rectifier G2, voltage and current transducers 101 Advances in Electrical and Computer Engineering Volume 15, Number 3, 2015 U1 ...
Terms matched: 1  -  Score: 3  -  1,263k
Year: 2015, Volume: 15, Number: 3
... ] To estimate the iron-loss resistance values, several periodic experiments were performed. In this case, the dc m 0.5 supply voltage U dc was acquired by an autotransformer and a 3-phase diode bridge rectifier, whereas the residual ac 0 0 100 200 300 400 500 600 700 800 900 component was filtered out by means of ...
Terms matched: 1  -  Score: 3  -  1,201k
Year: 2015, Volume: 15, Number: 3
... Advances in Electrical and Computer Engineering Volume 15, Number 3, 2015 Verification of Transformer Restricted Earth Fault Protection by using the Monte Carlo Method Jelisaveta P. KRSTIVOJEVIC ... the remanent flux pattern [28]. The remanent flux in cores of three-phase transformers Figure 3. The method of determining the parameters U s and S from ...
Terms matched: 2  -  Score: 137  -  1,566k
Year: 2015, Volume: 15, Number: 3
... PCB traces. from the secondary of the 4-kVA three-phase transformer During the testing procedure we have learned that the ... A part of the laboratory setup. The bulky three-phase transformers 0.02 are not shown. P D2 [W ... variable care should be taken when designing the converter PCB autotransformer. The primary of the variable layout in order ...
Terms matched: 4  -  Score: 57  -  2,048k
Year: 2015, Volume: 15, Number: 3
... correspond to the transient occurrences analyzed later in the where Le is equivalent generator and transformer inductance. paper. From the equations 1-8 follows that the accuracy of the ... , the appearance of harmonics, time presentations of four characteristic switching surges overload of transformers, significant neutral line currents were recorded: energization of an unloaded 35 kV ...
Terms matched: 2  -  Score: 8  -  1,174k
Year: 2015, Volume: 15, Number: 2
... to maximum power tracking via the current sensor, a line-commutated inverter module, a reference current instead of the firing angle. In addition, controller, and step-up transformer, which is shown in power factor can be controlled by changing firing angle of Fig. 3. Moreover, operating principle with switching SCRs. Thus, ...
Terms matched: 1  -  Score: 36  -  894k
Year: 2015, Volume: 15, Number: 2
... , M. Vakilian, E. Rahimpour, "A New Method for granularities from its coarse-grained structure are of large Detection and Evaluation of Winding Mechanical Faults in Transformer through Transfer Function Measurements", Advances in dimensions that those from the current steel block. Electrical and Computer Engineering, pp. 23-30, Vol. 11 ...
Terms matched: 1  -  Score: 3  -  1,187k
Result Pages: << Previous 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 Next >>


Search took 0.284 seconds


The search engine database includes all papers published after 2007, including titles, author names, abstracts, keywords, full papers text, references and citations. For papers published between 2001 and 2006, please visit the Archive section.


We invite you to try the most frequently used search terms:

system - power - control - fault - network - load - model - frequency - converter - transformer - harmonic - computer - algorithm - cancer - simulation - computer - estimate - optimal control - expert system - electromagnetic - interference - data transmission - neural network - electrocardiogram signal - model - cluster - design - wavelet - antenna - wireless sensor - coupling - robust - noise - signal processing - system identification - translation - nonlinear systems - induction motor - speed controller - shape optimization - fuzzy network - wireless sensor network


Website loading speed and performance optimization powered by: 


DNS Made Easy