Click to open the HelpDesk interface
AECE - Front page banner

Menu:


FACTS & FIGURES

JCR Impact Factor: 0.800
JCR 5-Year IF: 1.000
SCOPUS CiteScore: 2.0
Issues per year: 4
Current issue: Feb 2024
Next issue: May 2024
Avg review time: 77 days
Avg accept to publ: 48 days
APC: 300 EUR


PUBLISHER

Stefan cel Mare
University of Suceava
Faculty of Electrical Engineering and
Computer Science
13, Universitatii Street
Suceava - 720229
ROMANIA

Print ISSN: 1582-7445
Online ISSN: 1844-7600
WorldCat: 643243560
doi: 10.4316/AECE


TRAFFIC STATS

2,538,891 unique visits
1,009,450 downloads
Since November 1, 2009



Robots online now
Googlebot
ZoominfoBot
bingbot


SCOPUS CiteScore

SCOPUS CiteScore


SJR SCImago RANK

SCImago Journal & Country Rank




TEXT LINKS

Anycast DNS Hosting
FEATURED ARTICLES

Analysis of the Hybrid PSO-InC MPPT for Different Partial Shading Conditions, LEOPOLDINO, A. L. M., FREITAS, C. M., MONTEIRO, L. F. C.
Issue 2/2022

AbstractPlus






LATEST NEWS

2023-Jun-28
Clarivate Analytics published the InCites Journal Citations Report for 2022. The InCites JCR Impact Factor of Advances in Electrical and Computer Engineering is 0.800 (0.700 without Journal self-cites), and the InCites JCR 5-Year Impact Factor is 1.000.

2023-Jun-05
SCOPUS published the CiteScore for 2022, computed by using an improved methodology, counting the citations received in 2019-2022 and dividing the sum by the number of papers published in the same time frame. The CiteScore of Advances in Electrical and Computer Engineering for 2022 is 2.0. For "General Computer Science" we rank #134/233 and for "Electrical and Electronic Engineering" we rank #478/738.

2022-Jun-28
Clarivate Analytics published the InCites Journal Citations Report for 2021. The InCites JCR Impact Factor of Advances in Electrical and Computer Engineering is 0.825 (0.722 without Journal self-cites), and the InCites JCR 5-Year Impact Factor is 0.752.

2022-Jun-16
SCOPUS published the CiteScore for 2021, computed by using an improved methodology, counting the citations received in 2018-2021 and dividing the sum by the number of papers published in the same time frame. The CiteScore of Advances in Electrical and Computer Engineering for 2021 is 2.5, the same as for 2020 but better than all our previous results.

2021-Jun-30
Clarivate Analytics published the InCites Journal Citations Report for 2020. The InCites JCR Impact Factor of Advances in Electrical and Computer Engineering is 1.221 (1.053 without Journal self-cites), and the InCites JCR 5-Year Impact Factor is 0.961.

Read More »


SEARCH THE JOURNAL CONTENT


Enter one or more keywords to search for.
For exact phrase matching use quotation marks (e.g. "speed controller").
Note that '*' and '?' wildcards are supported.

Search for:

Results per page:

Match: any search words all search words

Search results for: transformer

158 results found.

16 pages of results.
Sort by relevance / Sorted by date ▼
Year: 2015, Volume: 15, Number: 1
... upon the efficiencies of DC/DC converters other hand, AC system had its transformer capable of high making up the system. These converters show varying voltage power ... distribution systems; also in case of DC system various replacing the distribution step down transformers currently voltage levels are used. Besides this, a back-up power found in ...
Terms matched: 2  -  Score: 63  -  1,408k
Year: 2015, Volume: 15, Number: 1
... signal. It managed to analyze and to [15] A. Abu-Siada, N. Hashemnia, S. Islam, M. Masoum, "Understanding power transformer frequency response analysis signatures", Electrical determine the degree of similarity and, to find differences Insulation Magazine, IEEE, vol.29, no.3, pp. 48-56 ...
Terms matched: 1  -  Score: 3  -  771k
Year: 2015, Volume: 15, Number: 1
... , MG5, MG6 are asked to provide their maximum transformer at a certain instant of time and the actual ... were kept over 0.96 p.u. However starting from the transformers' 80% nominal apparent power capacity with 8th ... original power of all the buses, lines' and transformer's resistances problem (1). Each iteration is ...
Terms matched: 3  -  Score: 27  -  798k
Year: 2015, Volume: 15, Number: 1
... realized in the through the grounded neutrals of the power transformer, model, which enables to determine the matrix ... power developed. The calculations were performed in the MATLAB transformers magnetic system [4 ], [10-13] ... . The total installed capacity of the power transformers and autotransformers at the power stations and the transformer substations in ...
Terms matched: 3  -  Score: 130  -  785k
Year: 2014, Volume: 14, Number: 3
... currently used in numerous fields, adjustments when the input voltage values vary in the range such as AC motor drives, adjustable AC sources, electric 10%. transformers, output voltage waveform restorers etc. These converters successfully replace alternative voltage variators II. CIRCUIT ANALYSIS using SCRs or TRIACs. Since operation frequencies are Figure 1 ...
Terms matched: 1  -  Score: 3  -  832k
Year: 2014, Volume: 14, Number: 3
... @p.lodz.pl 1 Abstract — This article describes the measurement transformer mineral oil or new environmentally friendly techniques used for ... the shapes recorded for mineral oil typically used in power transformers as an insulating medium [2, 3, ... , 9, 10, 12, 15-18]. This confirms that independently on the type of liquid, ...
Terms matched: 3  -  Score: 30  -  1,051k
Year: 2014, Volume: 14, Number: 3
... , because it distorts the regular waveform of the supply. The arcing generates transients, and these transients affect the railway system, including the track circuits, supply transformers, vehicle transformers, and other locomotives. (a) (b) (c) This paper presents a new approach for monitoring the Figure 2. ...
Terms matched: 1  -  Score: 6  -  1,144k
Year: 2014, Volume: 14, Number: 3
... . systems. Pre-condition: System operational conditions before the Example: A solar storm causes an overload in a materialization of the origin of a blackout, including weather transformer which then trips off the transformer, which then conditions, generation and load levels, significant scheduled creates low voltage in the local area. Thus, using ...
Terms matched: 1  -  Score: 16  -  712k
Year: 2014, Volume: 14, Number: 3
... , Number 3, 2014 A New Method of Improving Transformer Restricted Earth Fault Protection Jelisaveta P. KRSTIVOJEVIC, ... equal to one half of the signal protection of power transformers against internal faults is period. Also, the ... Number 3, 2014 Case 1: Ground fault outside transformer's protected zone. A fault occurred at the instant ...
Terms matched: 3  -  Score: 162  -  1,003k
Year: 2014, Volume: 14, Number: 3
... 3, by lumping the power 1/T (jω, D) are rational functions, there is a frequency ω0 source, the MOSFET switches and the transformer into the such that (ω0,) can be partitioned into subintervals of voltage source VS. For ease of notation we shall use equal length |2π ...
Terms matched: 1  -  Score: 1  -  800k
Result Pages: << Previous 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 Next >>


Search took 0.323 seconds


The search engine database includes all papers published after 2007, including titles, author names, abstracts, keywords, full papers text, references and citations. For papers published between 2001 and 2006, please visit the Archive section.


We invite you to try the most frequently used search terms:

system - power - control - fault - network - load - model - frequency - converter - transformer - harmonic - computer - algorithm - cancer - simulation - computer - estimate - optimal control - expert system - electromagnetic - interference - data transmission - neural network - electrocardiogram signal - model - cluster - design - wavelet - antenna - wireless sensor - coupling - robust - noise - signal processing - system identification - translation - nonlinear systems - induction motor - speed controller - shape optimization - fuzzy network - wireless sensor network


Website loading speed and performance optimization powered by: 