4/2010 - 18 |
Adaptive Passivity-Based Control of PEM Fuel Cell/Battery Hybrid Power Source for Stand-Alone ApplicationsTOFIGHI, A. , KALANTAR, A. |
Extra paper information in |
Click to see author's profile in SCOPUS, IEEE Xplore, Web of Science |
Download PDF (1,025 KB) | Citation | Downloads: 2,257 | Views: 6,174 |
Author keywords
adaptive passivity-based control, batteries, fuel cells, hybrid power systems, load management
References keywords
control(29), power(27), fuel(19), cell(17), energy(14), electronics(12), passivity(10), modeling(10), hybrid(10), dynamic(9)
Blue keywords are present in both the references section and the paper title.
About this article
Date of Publication: 2010-11-30
Volume 10, Issue 4, Year 2010, On page(s): 111 - 120
ISSN: 1582-7445, e-ISSN: 1844-7600
Digital Object Identifier: 10.4316/AECE.2010.04018
Web of Science Accession Number: 000284782700018
SCOPUS ID: 78649707648
Abstract
In this paper, a DC hybrid power source composed of PEM fuel cell as main source, Li-ion battery storage as transient power source and their power electronic interfacing is modelled based on Euler-Lagrange framework. Subsequently, adaptive passivity-based controllers are synthesized using the energy shaping and damping injection technique. Local asymptotic stability is insured as well. In addition, the power management system is designed in order to manage power flow between components. Evaluation of the proposed system and simulation of the hybrid system are accomplished using MATLAB/Simulink. Afterwards, linear PI controllers are provided for the purpose of comparison with proposed controllers responses. The results show that the outputs of hybrid system based on adaptive passivity-based controllers have a good tracking response, low overshoot, short settling time and zero steady-state error. The comparison of results demonstrates the robustness of the proposed controllers for reference DC voltage and resistive load changes. |
References | | | Cited By «-- Click to see who has cited this paper |
[1] C. Wang, M. H. Nehrir, S. R. Shaw, "Dynamic models and model validation for PEM fuel cells using electrical circuits," IEEE Trans. on Energy Conversion, vol. 20, Issue 2, pp. 442 - 451, 2005. [CrossRef] [Web of Science Times Cited 448] [SCOPUS Times Cited 605] [2] Z. Jiang, R.A. Dougal, "A hybrid fuel cell power supply with rapid dynamic response and high peak-power capacity," Twenty-First Annual IEEE Applied Power Electronics Conference and Exposition, APEC '06, pp. 1250-1255, 2006. [CrossRef] [3] J. M. Andujar, M. Segura, J. Vasallo, "A suitable model plant for control of the set fuel cell DC/DC converter," Renewable Energy vol. 33, Issue 4, pp. 813-826, April 2008. [CrossRef] [Web of Science Times Cited 68] [SCOPUS Times Cited 87] [4] S. M. Sharifi Asl, S. Rowshanzamir, M. H. Eikani, "Modelling and simulation of the steady-state and dynamic behavior of a PEM fuel cell," Energy, vol. 35, Issue 4, pp.1633-1646, April 2010. [CrossRef] [Web of Science Times Cited 104] [SCOPUS Times Cited 117] [5] M. J. Khan, M. T. Iqbal, "Dynamic modeling and simulation of a small wind-fuel cell hybrid energy system," Renewable Energy, vol. 30, Issue 3, pp. 421-439, March 2005. [CrossRef] [Web of Science Times Cited 185] [SCOPUS Times Cited 248] [6] M. Amirabadi, S. H. Farhangi, "Fuzzy control of hybrid fuel cell/battery power source in electric vehicle," 1st IEEE Conference on Industrial Electronics and Applications, pp. 1-5, 2006. [CrossRef] [SCOPUS Times Cited 13] [7] C. Wang, M. H. Nehrir, H. Gao, "Control of PEM fuel cell distributed generation systems," IEEE Trans. on Energy Conversion, vol. 21, Issue 2, pp. 586-595, 2006. [CrossRef] [Web of Science Times Cited 123] [SCOPUS Times Cited 179] [8] M. Uzunoglu, M. S. Alam, "Dynamic modeling, design and simulation of a PEM fuel cell/ultra-capacitor hybrid system for vehicular applications," Energy Conversion and Management, vol. 48, Issue 5, pp. 1544-1553, May 2007. [CrossRef] [Web of Science Times Cited 134] [SCOPUS Times Cited 182] [9] T. L. Skvarenina, "The power electronics handbook," USA: CRC Press, 2002. [PermaLink] [10] Z. Jiang, R. A. Dougal, "A compact digitally controlled fuel cell/battery hybrid power source," IEEE Trans. on Industrial Electronics, vol. 53, Issue 4, pp. 1094-1104, 2006. [CrossRef] [Web of Science Times Cited 144] [SCOPUS Times Cited 182] [11] C. H. Li, X. J. Zhu, G. Y. Cao, S. Sui, M. R. Hu, "Dynamic modeling and sizing optimization of stand-alone photovoltaic power systems using hybrid energy storage technology," Renewable Energy, vol. 34, Issue 3, pp. 815-826, March 2009. [CrossRef] [Web of Science Times Cited 281] [SCOPUS Times Cited 335] [12] M. T. Gencoglu, Z. Ural, "Design of a PEM fuel cell system for residential application," International Journal of Hydrogen Energy, vol.34, Issue 12, pp.5242-5248, June 2009. [CrossRef] [Web of Science Times Cited 133] [SCOPUS Times Cited 165] [13] M. J. Khan, M. T. Iqbal, "Dynamic modeling and simulation of a fuel cell generator," Fuel Cells, vol. 5, Issue 1, pp. 97-104, 2004. [14] M. Y. El-Sharkh, A. Rahman, M. S. Alam, A. A. Sakla, P. C. Byrne, T. Thomas, "Analysis of active and reactive power control of a stand-alone PEM fuel cell power plant," IEEE Trans. on Power Systems, vol. 19, Issue 4 , pp. 2022-2028, 2004. [CrossRef] [Web of Science Times Cited 74] [SCOPUS Times Cited 122] [15] Y. H. Li, S. S. Choi, S. Rajakaruna, "An analysis of the control and operation of a solid oxide fuel-cell power plant in an isolated system," IEEE Transactions on Energy Conversion, vol. 20, no. 2, pp. 381-387, 2005. [CrossRef] [Web of Science Times Cited 120] [SCOPUS Times Cited 155] [16] O. C. Onar, M. Uzunoglu, M.S. Alam, "Dynamic modeling, design and simulation of a wind/fuel cell/ultra-capacitor-based hybrid power generation system," Journal of Power Sources, vol. 161, Issue 1, pp. 707-722, October 2006. [CrossRef] [Web of Science Times Cited 165] [SCOPUS Times Cited 221] [17] C. Batlle, A. Doria-Cerezo, E. Fossas, "Bidirectional power flow control of a power converter using passive hamiltonian techniques," International Journal Circuit Theory Application, vol. 36, pp. 769-788, 2008. [CrossRef] [Web of Science Times Cited 24] [SCOPUS Times Cited 27] [18] D. Cortes, J. Alvarez, J. Alvarez, "Robust Control of the Boost Converter," International Conference on Industrial Electronics and Control Applications," ICIECA, pp. 1-6, 2005. [CrossRef] [SCOPUS Times Cited 9] [19] S. K. Mazumder, A. H. Nayfeh, D. Borojevic, "Robust control of parallel DC-DC buck converters by combining integral-variable-structure and multiple-sliding-surface control schemes," IEEE Trans. on Power Electronics, vol. 17, Issue 3, pp. 428-437, 2002. [CrossRef] [Web of Science Times Cited 118] [SCOPUS Times Cited 147] [20] D. E. Kim, D. C. Lee, "Feedback linearization control of three-phase AC/DC PWM converters with LCL input filters," 7th International Conference on Power Electronics, ICPE '07, pp.766-771, October 22-26, 2007. [CrossRef] [SCOPUS Times Cited 14] [21] N. Vazquez, C. Hernandez, J. Alvarez, J. Arau, "Sliding mode control for DC/DC converters: A new sliding surface," IEEE International Symposium on Industrial Electronics, ISIE '03. pp. 422-426, 2003. [CrossRef] [SCOPUS Times Cited 26] [22] R. Leyva, A. Cid-Pastor, C. Alonso, I. Queinnec, S. Tarbouriech, L. Martinez-Salamero, "Passivity-based integral control of a boost converter for large-signal stability," IEE Proceedings-Control Theory and Applications, vol. 153, Issue 2, pp. 139-146, 2006. [CrossRef] [Web of Science Times Cited 71] [SCOPUS Times Cited 83] [23] R. Ortega, A. Van Der Schaft, B. Maschke, G. Escobar, "Interconnection and damping assignment passivity-based control of port-controlled hamiltonian systems," Automatica, vol. 38, Issue 4, pp. 585-596, April 2002. [CrossRef] [Web of Science Times Cited 1084] [SCOPUS Times Cited 1408] [24] R. Ortega, A. Loria, P. J. Nicklasson, H. Sira-Ramirez, "Passivity based Control of euler-lagrange systems: mechanical, electrical and electrochemical applications," London, U.K.: Springer-Verlag, 1998. [PermaLink] [25] J. M. A. Scherpen, D. Jeltsema, J. B. Klaassens, "Lagrangian modeling of switching electrical networks," Systems & Control Letters, vol. 48, Issue 5, pp. 365-374, April 2003. [CrossRef] [Web of Science Times Cited 45] [SCOPUS Times Cited 50] [26] A. Doria-Cerezo, "Modeling, simulation and control of a doubly-fed induction machine controlled by a back-to-back converter," PhD Destination, Technical University of Catalonia, 2006. [27] A. Kwasinski, P. T. Krein, "Passivity-based control of buck converters with constant-power loads," IEEE Power Electronics Specialists Conference, PESC '07, pp. 259-265, 2007. [CrossRef] [Web of Science Times Cited 83] [SCOPUS Times Cited 104] [28] P. Wang, J. Wang, Z. Xu, "Passivity-based control of three phase voltage source PWM rectifiers based on PCHD model," International Conference on Electrical Machines and Systems, ICEMS '08, pp. 1126-1130, 2008. [29] T. S. Lee, "Lagrangian modeling and passivity-based control of three-phase AC/DC voltage-source converters," IEEE Trans. on Industrial Electronics, vol. 51, Issue 4, pp. 892-902, August 2004. [CrossRef] [Web of Science Times Cited 189] [SCOPUS Times Cited 254] [30] H. Komurcugil, "Steady-state analysis and passivity-based control of single-phase PWM current-source inverters," IEEE Trans. on Industrial Electronics, vol. 57, Issue 3, pp. 1026-1030, March 2010. [CrossRef] [Web of Science Times Cited 62] [SCOPUS Times Cited 83] [31] M. Y. Ayad, M. Becherif, A. Henni, A. Aboubou, M. Wack, S. Laghrouche, "Passivity-based control applied to DC hybrid power source using fuel cell and supercapacitors," Energy Conversion and Management, vol. 51, Issue 7, pp. 1468-1475, 2010. [CrossRef] [Web of Science Times Cited 58] [SCOPUS Times Cited 74] [32] H. Sira-Ramirez, M. Rios-Bolivar, A. S. I. Zinober, "Adaptive dynamical input-output linearization of DC to DC Power converters: a backstepping approach," International Journal Robust and Nonlinear Control, vol. 7, pp. 279-96, 1997. [33] H. Sira-Ramirez, R. Ortega, M. Garci-Esteban, "Adaptive passivity-based control of average DC-to-DC power converters models," International Journal Adaptive Control Signal Process, vol. 12, pp. 63-80, 1998. [34] K. S. Jeong, W. Y. Lee, C. S. Kim, "Energy management strategies of a fuel cell/battery hybrid system using fuzzy logics," Journal of Power Sources, vol. 145, Issue 2, pp. 319-26, 2005. [CrossRef] [Web of Science Times Cited 116] [SCOPUS Times Cited 156] [35] S. A. Khateeb, M. M. Farid, J. R. Selman, S. Al-Hallaj, "Mechanical-electrochemical modeling of Li-ion battery designed for an electric scooter," Journal of Power Sources, vol.1 58, Issue 1, pp.673-678, 2006. [CrossRef] [Web of Science Times Cited 23] [SCOPUS Times Cited 30] [36] M. Durr, A. Cruden, S. Gair, J. R. McDonald, "Dynamic model of a lead acid battery for use in a domestic fuel cell system," Journal of Power Sources, vol. 161, Issue 6, pp. 1400-1411, 2006. [CrossRef] [Web of Science Times Cited 152] [SCOPUS Times Cited 209] [37] M. Chen, G. A. Rinco'n-Mora, "Accurate electrical battery model capable of predicting runtime and I-V performance," IEEE Trans. on Energy Conversion,vol.21, Issue 2, pp. 504-511, 2006. [CrossRef] [Web of Science Times Cited 1550] [SCOPUS Times Cited 1993] [38] G. Escobar, R. Ortega, H. Sira-Ramirez, J. P. Vilain, I. Zein, "An experimental comparison of several nonlinear controllers for power converters," IEEE Control Systems Magazine, vol. 19, Issue 1, pp. 66-82, 1999. [CrossRef] [Web of Science Times Cited 146] [SCOPUS Times Cited 183] [39] R. W. Erickson. "Fundamentals of Power Electronics Instructor's slides," [Online]. Available: Temporary on-line reference link removed - see the PDF document [40] R. Dorf, "Modern control system," Prentice Hall, 11nd Ed. August 10, 2007. [41] Specifications of Polymer Lithium Ion Battery, Model: PL-383562. [42] M. Becherif, M. Y. Ayad, A. Miraoui, "Modeling and passivity-based control of hybrid sources: fuel cell and supercapacitors," 41st IAS Annual Meeting Industry Applications Conference, pp. 1134-1139, 2006. Web of Science® Citations for all references: 5,700 TCR SCOPUS® Citations for all references: 7,461 TCR Web of Science® Average Citations per reference: 133 ACR SCOPUS® Average Citations per reference: 174 ACR TCR = Total Citations for References / ACR = Average Citations per Reference We introduced in 2010 - for the first time in scientific publishing, the term "References Weight", as a quantitative indication of the quality ... Read more Citations for references updated on 2024-11-16 11:50 in 210 seconds. Note1: Web of Science® is a registered trademark of Clarivate Analytics. Note2: SCOPUS® is a registered trademark of Elsevier B.V. Disclaimer: All queries to the respective databases were made by using the DOI record of every reference (where available). Due to technical problems beyond our control, the information is not always accurate. Please use the CrossRef link to visit the respective publisher site. |
Faculty of Electrical Engineering and Computer Science
Stefan cel Mare University of Suceava, Romania
All rights reserved: Advances in Electrical and Computer Engineering is a registered trademark of the Stefan cel Mare University of Suceava. No part of this publication may be reproduced, stored in a retrieval system, photocopied, recorded or archived, without the written permission from the Editor. When authors submit their papers for publication, they agree that the copyright for their article be transferred to the Faculty of Electrical Engineering and Computer Science, Stefan cel Mare University of Suceava, Romania, if and only if the articles are accepted for publication. The copyright covers the exclusive rights to reproduce and distribute the article, including reprints and translations.
Permission for other use: The copyright owner's consent does not extend to copying for general distribution, for promotion, for creating new works, or for resale. Specific written permission must be obtained from the Editor for such copying. Direct linking to files hosted on this website is strictly prohibited.
Disclaimer: Whilst every effort is made by the publishers and editorial board to see that no inaccurate or misleading data, opinions or statements appear in this journal, they wish to make it clear that all information and opinions formulated in the articles, as well as linguistic accuracy, are the sole responsibility of the author.