1/2022 - 2 |
Modeling, Control, and Experimental Verification of a 500 kW DFIG Wind TurbineAYKUT, O., ULU, C. , KOMURGOZ, G. |
Extra paper information in |
Click to see author's profile in SCOPUS, IEEE Xplore, Web of Science |
Download PDF (1,882 KB) | Citation | Downloads: 1,016 | Views: 1,828 |
Author keywords
doubly fed induction generator, modeling control, renewable energy source, wind energy
References keywords
wind(36), power(21), control(21), energy(19), induction(14), doubly(14), generator(12), system(11), turbines(10), turbine(8)
Blue keywords are present in both the references section and the paper title.
About this article
Date of Publication: 2022-02-28
Volume 22, Issue 1, Year 2022, On page(s): 13 - 20
ISSN: 1582-7445, e-ISSN: 1844-7600
Digital Object Identifier: 10.4316/AECE.2022.01002
Web of Science Accession Number: 000762769600003
SCOPUS ID: 85126826344
Abstract
In wind turbine applications, an accurate turbine model and effective control algorithms are needed to ensure power flow in accordance with grid standards and design criteria. However, in many studies, only model simulation results are given or the derived models are validated by using only small-scale prototypes. This article presents the modeling, control, and experimental verification of a 500kW doubly fed induction generator (DFIG) wind turbine. The entire model is considered to be a collection of subsystems that are individually modeled and then put together to obtain the whole wind turbine model. The model includes a DFIG, a back-to-back converter, and a control system. In the control system, control of the back-to-back converter, the blade angle control and the maximum power point tracking control are performed to provide effective energy conversion performances for different operation conditions. To validate the derived DFIG turbine model, the results of three experimental tests obtained from a 500kW DFIG wind turbine prototype are used. These test results include both subsynchronous and super-synchronous operation conditions. The test results are compared to simulation results obtained by using the derived turbine model. The accuracy of the model is validated by the comparison results. |
References | | | Cited By «-- Click to see who has cited this paper |
[1] E. Rezaei, A. Tabesh and M. Ebrahimi, "Dynamic model and control of DFIG wind energy systems based on power transfer matrix," IEEE Transactions on Power Delivery, Vol. 27, No. 3, pp. 1485-1493, 2012. [CrossRef] [Web of Science Times Cited 38] [SCOPUS Times Cited 48] [2] P. Tchakoua, and R. Wamkeue, "A review of concepts and methods for wind turbines condition monitoring," in Proc. 2013 World Congress on Computer and Information Technology (WCCIT), 2013, pp. 1-9. [CrossRef] [SCOPUS Times Cited 34] [3] J. Bhukya and V. Mahajan, "Modelling of power system stabilizer for double fed induction generator based wind power system," in Proc. IEEE 8th Power India International Conference (PIICON), 2018, pp. 1-6. [CrossRef] [SCOPUS Times Cited 6] [4] I. Yaichi, A. Semmah, M. Djlaila, A. Harrouz, S. Mansouri and Y. Bakou, "Modelling and control of doubly ed induction machine, application for a wind turbine system," in Proc. International Renewable and Sustainable Energy Conference (IRSEC), 2016, pp. 450-455. [CrossRef] [SCOPUS Times Cited 11] [5] A. D. Hansen and F. Lov, "Review of contemporary wind turbine concepts and their market penetration," Wind Engineering, vol. 28, no. 3, pp. 247-263, 2004. [CrossRef] [SCOPUS Times Cited 181] [6] M. Singh and S. Santoso, Dynamic models for wind turbines and wind power plants, NREL, NREL/SR-5500-52780, University of Texas, 2011. [CrossRef] [7] W. Qiao, "Dynamic modeling and control of doubly fed induction generators driven by wind turbines," in Proc. IEEE/PES Power Systems Conference and Exposition, 2009, pp. 1-8. [CrossRef] [SCOPUS Times Cited 101] [8] K. E. Okedu, S. M. Muyeen and R. Takahashi, "Wind farm stabilization by using DFIG with current controlled voltage source converters taking grid codes into consideration," IEEJ Transactions on Power and Energy, vol. 132, no. 3, pp. 251-259, 2012. [CrossRef] [SCOPUS Times Cited 16] [9] L. Barote, C. Marinescu, "Modeling and operational testing of an isolated variable speed PMSG wind turbine with battery energy storage," Advances in Electrical and Computer Engineering, vol. 12, no. 2, pp. 81-88, 2012. [CrossRef] [Full Text] [Web of Science Times Cited 15] [SCOPUS Times Cited 18] [10] M. S. Alam, M. A. Y. Abido, "Fault ride through capability enhancement of a large-scale PMSG wind system with bridge type fault current limiters," Advances in Electrical and Computer Engineering, vol. 18, no. 1, pp. 43-50, 2018. [CrossRef] [Full Text] [Web of Science Times Cited 21] [SCOPUS Times Cited 26] [11] M. A. S. Ali, "Utilizing Active Rotor-Current References for Smooth Grid Connection of a DFIG-Based Wind-Power System," Advances in Electrical and Computer Engineering, vol. 20, no. 4, pp. 91-98, 2020. [CrossRef] [Full Text] [Web of Science Times Cited 8] [SCOPUS Times Cited 9] [12] Y. Lei, A. Mullane, G. Lightbody and R. Yacamini "Modeling of the wind turbine with a doubly fed induction generator for grid integration studies," IEEE Transactions on Energy Conversion, vol. 21, no. 1, pp. 257-264, 2006. [CrossRef] [Web of Science Times Cited 435] [SCOPUS Times Cited 638] [13] A. D. Hansen and G. Michalke, "Fault ride-through capability of DFIG wind turbines," Renewable Energy, vol. 32, no. 9, pp. 1594-1610, 2007. [CrossRef] [Web of Science Times Cited 216] [SCOPUS Times Cited 309] [14] T. Petru and T. Thiringer, "Modeling of wind turbines for power system studies," IEEE Transactions on Power Systems, vol. 17, no. 4, pp. 1132-1139, 2002. [CrossRef] [Web of Science Times Cited 154] [SCOPUS Times Cited 244] [15] P. Ledesma and J. Usaola, "Doubly fed induction generator model for transient stability analysis," IEEE Transactions on Energy Conversion, vol. 20, no. 2, pp. 388-397, 2005. [CrossRef] [Web of Science Times Cited 211] [SCOPUS Times Cited 294] [16] S. Peresadaa, A. Tillib and A. Tonielli, "Power control of a doubly fed induction machine via output feedback," Control Engineering Practice, vol. 12, no. 1, pp. 41-57, 2004. [CrossRef] [Web of Science Times Cited 61] [SCOPUS Times Cited 83] [17] J. L. Rodrfguez-Amenedo, S. Arnaltes and M. A. Rodrfguez, "Operation and coordinated control of fixed and variable speed wind farms," Renewable Energy, vol. 33, no. 3, pp. 406-414, 2007. [CrossRef] [Web of Science Times Cited 47] [SCOPUS Times Cited 61] [18] A. D. Hansen, P. Sorensen, F. Iov and F. Blaabjerg, "Centralised power control of wind farm with doubly fed induction generators," Renewable Energy, vol. 31, no. 7, pp. 935-951 2005. [CrossRef] [Web of Science Times Cited 304] [SCOPUS Times Cited 424] [19] A. Kadri, H. Marzougui, K. Omrani and F. Bacha, "Improved direct power contro lof a doubly fed induction generator based wind energy conversion system," in Proc. 5th International Conference on Control, Decision and Information Technologies (CoDIT), 2018, pp. 707-712. [CrossRef] [SCOPUS Times Cited 5] [20] B. Bensahila, M. E. Amine, A. Ahmed, M.B. Houari and D. Mouloud, "Modeling, simulation and control of a doubly-fed induction generator for wind energy conversion systems," International Journal of Power Electronics and Drive System (IJPEDS), vol. 11, no. 3, pp. 1197-1210, 2020. [CrossRef] [21] N. G. Lantewa and N. Magaji, "Control of doubly fed induction generator of variable speed wind turbine system using neural network," in Proc. International Conference and Utility Exhibition on Green Energy for Sustainable Development (ICUE), 2018, pp. 1-6. [CrossRef] [SCOPUS Times Cited 3] [22] A. Boumassata, D. Kerdoun, "Modeling, simulation and control of wind energy conversion system based on doubly fed induction generator and cycloconverter," Advances in Electrical and Computer Engineering, vol. 14, no. 2, pp. 43-48, 2014. [CrossRef] [Full Text] [Web of Science Times Cited 7] [SCOPUS Times Cited 9] [23] D. Kairus, R. Wamkeue, B. Belmadani, M. Benghanem, "Variable structure control of DFIG for wind power generation and harmonic current mitigation," Advances in Electrical and Computer Engineering, vol. 10, no. 4, pp. 167-174, 2010. [CrossRef] [Full Text] [Web of Science Times Cited 10] [SCOPUS Times Cited 13] [24] J. Fortman, Modeling of wind turbines with doubly fed generator system, Springer Fachmedien Wiesbaden, 2015. [CrossRef] [SCOPUS Times Cited 29] [25] R. Melicio, V. M. F. Mendes and J. P. S. Catalao, "Wind turbines with permanent magnet synchronous generator and full-power converters: modeling, control and simulation," in Wind Turbines, London, United Kingdom: IntechOpen, pp. 465-494, 2011. [CrossRef] [26] W. Ende and H. Shenghua, "Robust control of the three-phase voltage-source pwm rectifier using EKF load current observer," Przeglad Elektrotechniczny, vol. 89, no. 3, pp. 189-193, 2013 [27] N. P. Redd and P. Hymavathi, "Mitigation of harmonics by three-phase voltage source pwm rectifier," International Journal of Scientific and Research Publications, vol. 2, no. 9, pp. 1-4, 2012 [28] L. Yu, R. Li and L. Xu, "Distributed PLL-based control of offshore wind turbines connected with diode-rectifier based HVDC systems," IEEE Transactions on Power Delivery, vol. 33, no. 3, pp. 1328-1336, 2018. [CrossRef] [Web of Science Times Cited 79] [SCOPUS Times Cited 133] [29] F. K. A. Lima, A. Luna and P. Rodriquez, "Study of a simplified model for DFIG-based wind turbines," in Proc. IEEE Energy Conversion Congress and Exposition, 2009, pp. 345-349. [CrossRef] [SCOPUS Times Cited 4] [30] Y. S. Rao and A. J. Laxmi, "Direct torque control of doubly fed induction generator based wind turbine under voltage dips," International Journal of Advances in Engineering & Technology, vol. 3, no. 2, pp. 711-720, 2012 [31] B. Pimple, B., V. Y. Vekhande and B. G. Fernandes, "New direct torque control of DFIG under balanced and unbalanced grid voltage," in Proc. TENCON 2010 - 2010 IEEE Region 10 Conference, 2010, pp. 2154-2158. [CrossRef] [Web of Science Times Cited 12] [SCOPUS Times Cited 13] [32] J. Thongam and M. Quhrouche, "MPPT control methods in wind energy conversion systems," Fundamental and advanced topics in wind power, vol. 1, pp. 339-360, 2011. [CrossRef] [33] M. A. Abdullah, A. H. M. Yatim, C. W. Tan and R. Saidur, "A review of maximum power point tracking algorithms for wind energy systems," Renewable and Sustainable Energy Reviews, vol. 16, no. 5, pp. 3220-3227, 2012. [CrossRef] [Web of Science Times Cited 524] [SCOPUS Times Cited 687] [34] A. Hwas and R. Katebi, "Wind turbine control using PI pitch angle controller," in Proc. IFAC Conference on Advances in PID Control, 2012; vol. 45, no. 3, pp. 241-246. [CrossRef] [SCOPUS Times Cited 93] [35] Y. Sirouni, S. Hani, N. Naseri, A. Aghmadi and K. Harouri, "Design and control of small scale wind turbine emulator with a DC motor," in Proc. 6th International Renewable and Sustainable Energy Conference (IRSEC), Morocco, 2018, pp. 1-6. [CrossRef] [SCOPUS Times Cited 12] [36] S. K. Salman and B. Badrzadeh, "New approach for modelling doubly-fed induction generator (DFIG) for grid-connection studies," in Proc. European Wind Energy Conference and Exhibition, London, 2004 [37] C. Ulu and G. Komurgoz, "Electrical design and testing of a 500 kW doubly fed induction generator for wind power applications," Turkish Journal of Electrical Engineering and Computer Sciences, vol. 25, no. 2, pp. 1278-1290, 2017. [CrossRef] [Web of Science Times Cited 3] [SCOPUS Times Cited 3] Web of Science® Citations for all references: 2,145 TCR SCOPUS® Citations for all references: 3,507 TCR Web of Science® Average Citations per reference: 56 ACR SCOPUS® Average Citations per reference: 92 ACR TCR = Total Citations for References / ACR = Average Citations per Reference We introduced in 2010 - for the first time in scientific publishing, the term "References Weight", as a quantitative indication of the quality ... Read more Citations for references updated on 2024-11-20 21:07 in 223 seconds. Note1: Web of Science® is a registered trademark of Clarivate Analytics. Note2: SCOPUS® is a registered trademark of Elsevier B.V. Disclaimer: All queries to the respective databases were made by using the DOI record of every reference (where available). Due to technical problems beyond our control, the information is not always accurate. Please use the CrossRef link to visit the respective publisher site. |
Faculty of Electrical Engineering and Computer Science
Stefan cel Mare University of Suceava, Romania
All rights reserved: Advances in Electrical and Computer Engineering is a registered trademark of the Stefan cel Mare University of Suceava. No part of this publication may be reproduced, stored in a retrieval system, photocopied, recorded or archived, without the written permission from the Editor. When authors submit their papers for publication, they agree that the copyright for their article be transferred to the Faculty of Electrical Engineering and Computer Science, Stefan cel Mare University of Suceava, Romania, if and only if the articles are accepted for publication. The copyright covers the exclusive rights to reproduce and distribute the article, including reprints and translations.
Permission for other use: The copyright owner's consent does not extend to copying for general distribution, for promotion, for creating new works, or for resale. Specific written permission must be obtained from the Editor for such copying. Direct linking to files hosted on this website is strictly prohibited.
Disclaimer: Whilst every effort is made by the publishers and editorial board to see that no inaccurate or misleading data, opinions or statements appear in this journal, they wish to make it clear that all information and opinions formulated in the articles, as well as linguistic accuracy, are the sole responsibility of the author.