Click to open the HelpDesk interface
AECE - Front page banner

Menu:


FACTS & FIGURES

JCR Impact Factor: 0.700
JCR 5-Year IF: 0.700
SCOPUS CiteScore: 1.8
Issues per year: 4
Current issue: May 2024
Next issue: Aug 2024
Avg review time: 57 days
Avg accept to publ: 60 days
APC: 300 EUR


PUBLISHER

Stefan cel Mare
University of Suceava
Faculty of Electrical Engineering and
Computer Science
13, Universitatii Street
Suceava - 720229
ROMANIA

Print ISSN: 1582-7445
Online ISSN: 1844-7600
WorldCat: 643243560
doi: 10.4316/AECE


TRAFFIC STATS

2,654,064 unique visits
1,051,258 downloads
Since November 1, 2009



Robots online now
bingbot
Googlebot


SCOPUS CiteScore

SCOPUS CiteScore


SJR SCImago RANK

SCImago Journal & Country Rank




TEXT LINKS

Anycast DNS Hosting
MOST RECENT ISSUES

 Volume 24 (2024)
 
     »   Issue 2 / 2024
 
     »   Issue 1 / 2024
 
 
 Volume 23 (2023)
 
     »   Issue 4 / 2023
 
     »   Issue 3 / 2023
 
     »   Issue 2 / 2023
 
     »   Issue 1 / 2023
 
 
 Volume 22 (2022)
 
     »   Issue 4 / 2022
 
     »   Issue 3 / 2022
 
     »   Issue 2 / 2022
 
     »   Issue 1 / 2022
 
 
 Volume 21 (2021)
 
     »   Issue 4 / 2021
 
     »   Issue 3 / 2021
 
     »   Issue 2 / 2021
 
     »   Issue 1 / 2021
 
 
  View all issues  


FEATURED ARTICLE

Application of the Voltage Control Technique and MPPT of Stand-alone PV System with Storage, HIVZIEFENDIC, J., VUIC, L., LALE, S., SARIC, M.
Issue 1/2022

AbstractPlus






LATEST NEWS

2024-Jun-20
Clarivate Analytics published the InCites Journal Citations Report for 2023. The InCites JCR Impact Factor of Advances in Electrical and Computer Engineering is 0.700 (0.700 without Journal self-cites), and the InCites JCR 5-Year Impact Factor is 0.600.

2023-Jun-28
Clarivate Analytics published the InCites Journal Citations Report for 2022. The InCites JCR Impact Factor of Advances in Electrical and Computer Engineering is 0.800 (0.700 without Journal self-cites), and the InCites JCR 5-Year Impact Factor is 1.000.

2023-Jun-05
SCOPUS published the CiteScore for 2022, computed by using an improved methodology, counting the citations received in 2019-2022 and dividing the sum by the number of papers published in the same time frame. The CiteScore of Advances in Electrical and Computer Engineering for 2022 is 2.0. For "General Computer Science" we rank #134/233 and for "Electrical and Electronic Engineering" we rank #478/738.

2022-Jun-28
Clarivate Analytics published the InCites Journal Citations Report for 2021. The InCites JCR Impact Factor of Advances in Electrical and Computer Engineering is 0.825 (0.722 without Journal self-cites), and the InCites JCR 5-Year Impact Factor is 0.752.

2022-Jun-16
SCOPUS published the CiteScore for 2021, computed by using an improved methodology, counting the citations received in 2018-2021 and dividing the sum by the number of papers published in the same time frame. The CiteScore of Advances in Electrical and Computer Engineering for 2021 is 2.5, the same as for 2020 but better than all our previous results.

Read More »


    
 

  2/2024 - 2

Simulation for Overall Moisture Distribution and Effects on the Electric Field of OIP Bushing Under Different Damp Defects

YANG, H. See more information about YANG, H. on SCOPUS See more information about YANG, H. on IEEExplore See more information about YANG, H. on Web of Science, ZHAO, S. See more information about  ZHAO, S. on SCOPUS See more information about  ZHAO, S. on SCOPUS See more information about ZHAO, S. on Web of Science, ZHOU, F. See more information about  ZHOU, F. on SCOPUS See more information about  ZHOU, F. on SCOPUS See more information about ZHOU, F. on Web of Science, CHEN, J. See more information about  CHEN, J. on SCOPUS See more information about  CHEN, J. on SCOPUS See more information about CHEN, J. on Web of Science, DUAN, Y. See more information about DUAN, Y. on SCOPUS See more information about DUAN, Y. on SCOPUS See more information about DUAN, Y. on Web of Science
 
View the paper record and citations in View the paper record and citations in Google Scholar
Click to see author's profile in See more information about the author on SCOPUS SCOPUS, See more information about the author on IEEE Xplore IEEE Xplore, See more information about the author on Web of Science Web of Science

Download PDF pdficon (3,875 KB) | Citation | Downloads: 158 | Views: 166

Author keywords
dielectric constant, electromagnetic fields, finite element analysis, moisture measurement, oil insulation

References keywords
insulation(15), power(13), moisture(13), transformer(10), paper(9), tdei(7), diffusion(7), transformers(6), liao(6), board(6)
Blue keywords are present in both the references section and the paper title.

About this article
Date of Publication: 2024-05-31
Volume 24, Issue 2, Year 2024, On page(s): 11 - 20
ISSN: 1582-7445, e-ISSN: 1844-7600
Digital Object Identifier: 10.4316/AECE.2024.02002
SCOPUS ID: 85195677892

Abstract
Quick view
Full text preview
The insulation status of oil-impregnated paper (OIP) bushings directly indicates their operational condition. Damp defects constitute the primary factor contributing to the deterioration of oil-paper insulation. In this paper, the overall moisture distribution of capacitor cores with three damp defects (steady-state, transient, anzd tail moisture damp defect) and its effect on the electric field were studied. A moisture diffusion model for OIP bushing was established based on Finite Element Method (FEM) software, and it was also verified by moisture diffusion experiments. Then, the overall moisture distribution of the capacitor core under three damp defects was investigated. The findings indicate significant variation in the overall moisture distribution of the capacitor core influenced by factors such as aluminum foil and temperature. Furthermore, the relative permittivity of the oil-impregnated paper was computed. Subsequently, the impact of various moisture-induced defects on the electric field was determined. Simulation results unveiled distortion in the electric field of each electrode within the capacitor core. Specifically, the electric field of the zero electrode increased, while that of the outermost electrode decreased in all three damp defect scenarios. The conclusions drawn can thus be used for intelligent operation and condition assessment of OIP bushings.


References | Cited By  «-- Click to see who has cited this paper

[1] P. Liu, Z. Peng, and X. Zhang, "Analysis of the insulation structure and electrical distribution of 1100 kV OIP condenser transformer bushings in China," IEEJ Electr. Electron. Eng. vol. 7(1), pp.7-12, Jan. 2012.
[CrossRef] [Web of Science Times Cited 13] [SCOPUS Times Cited 5]


[2] A. K. Lokhanin, T. I. Morozova, G. Y. Shneider, V. V. Sokolov, and V. M. Chornogotsky, "Internal insulation failure mechanisms of HV equipment under service conditions," CIGRE: Paris, France, 2002

[3] A. Setayeshmehr, A. Akbari, H. Borsi, and E. Gockenbach, "On-line monitoring and diagnoses of power transformer bushings," IEEE Trans. Dielectr. Electr. Insul., vol. 13(3), pp. 608-615, Jun. 2006.
[CrossRef] [Web of Science Times Cited 67] [SCOPUS Times Cited 105]


[4] D. Wang, L. Zhou, H. Li, W. Liao, X. Xu, and L. Guo, "Moisture estimation for oil-immersed bushing based on FDS method: at a reference temperature," IET Gener. Transmiss. Distrib., vol. 12(10), pp. 2480-2486, May 2018.
[CrossRef] [Web of Science Times Cited 27] [SCOPUS Times Cited 37]


[5] D. Wang, L. Zhou, W. Liao, A. Wang, X. Xu, and L. Guo, "Moisture estimation for oil-immersed bushing based on FDS method: Field application," IET Gener. Transm. Distrib., vol. 12(11), pp. 2762-2769, Jun. 2018.
[CrossRef] [Web of Science Times Cited 12] [SCOPUS Times Cited 18]


[6] Y. Cui, H. Ma, T. K. Saha, C. Ekanayake and D. Martin, "Moisture-dependent thermal modelling of power transformer," IEEE Trans. Power Del., vol. 31(5), pp. 2140-2150, Oct. 2016.
[CrossRef] [Web of Science Times Cited 50] [SCOPUS Times Cited 55]


[7] D. Martin, C. Perkasa, and N. Lelekakis, "Measuring paper water content of transformers: A new approach using cellulose isotherms in nonequilibrium conditions," IEEE Trans. Power Del., vol. 28(3), pp. 1433-1439, Jul. 2013.
[CrossRef] [Web of Science Times Cited 48] [SCOPUS Times Cited 57]


[8] T. V. Oommen and T. A. Prevost, "Cellulose insulation in oil-filled power transformers: Part II - Maintaining insulation integrity and life," IEEE Electr. Insul. Mag., vol. 22, pp. 5-14, Mar. 2006.
[CrossRef] [Web of Science Times Cited 160] [SCOPUS Times Cited 219]


[9] V. G. Arakelian and I. Fofana, "Water in oil-filled high-voltage equipment. Part 1: States, solubility, and equilibrium in insulating materials," IEEE Electr. Insul. Mag., vol. 23(4), pp. 15-27, Jul. 2007.
[CrossRef] [Web of Science Times Cited 16] [SCOPUS Times Cited 86]


[10] D. Martin and T. Saha, "A review of the techniques used by utilities to measure the water content of transformer insulation paper," IEEE Electr. Insul. Mag., vol. 33(3), pp. 8-16, May. 2017.
[CrossRef] [Web of Science Times Cited 41] [SCOPUS Times Cited 50]


[11] T. V. Oommen, "Moisture equilibrium in paper-oil insulation systems," EIC 6th Electrical/Electronical Insulation Conference, IL, USA, pp. 162-166, Oct. 1983.
[CrossRef] [SCOPUS Times Cited 138]


[12] J. Li, Z. Zhang, S. Grzybowski, and Y. Liu, "Characteristics of moisture diffusion in vegetable oil-paper insulation," IEEE Trans. Dielectr. Electr. Insul., vol. 19(5), pp.1650-1656, Jun. 2012.
[CrossRef] [Web of Science Times Cited 37] [SCOPUS Times Cited 55]


[13] W. A. Fessler, T. O. Rouse, W. J. McNutt and O. R. Compton, "A refined mathematical model for predication of bubble evolution in transformers," IEEE Trans. Power Delivery, vol. 4(1), pp. 391-404, Oct. 1987.
[CrossRef] [Web of Science Times Cited 45] [SCOPUS Times Cited 59]


[14] W. W. Guidi and H. P. Fullerton, "Mathematical methods for prediction of moisture take-up and removal in large power transformers," IEEE Power Eng. Soc. (PES) Winter Power Meeting, New York, USA, pp. 242-244, 1974

[15] Y. Du, A. V. Mamishev, B. C. Lesieutre and M. Zahn, "Measurement of moisture diffusion as a function of temperature and moisture concentration in transformer pressboard," IEEE Conf. Electr. Insul. Dielectr. Phenomena (CEIDP), GA, USA, pp. 341-344, Oct. 1998.
[CrossRef]


[16] R. Villarroel, D. F. Garcia, B. Garcia, and J. C. Burgos, "Diffusion coefficient in transformer pressboard insulation. Part 2: Mineral oil impregnated," IEEE Trans. Dielectr. Electr. Insul., vol. 21(1), pp. 394-402, Feb. 2014.
[CrossRef] [Web of Science Times Cited 16] [SCOPUS Times Cited 21]


[17] R. Villarroel, D. F. Garcia, B. Garcia, and J. C. Burgos, "Moisture diffusion coefficients of transformer pressboard insulation impregnated with natural esters," IEEE Trans. Dielectr. Electr. Insul., vol. 22(1), pp, 581-589, Feb. 2015.
[CrossRef] [Web of Science Times Cited 13] [SCOPUS Times Cited 20]


[18] M. Gao, Q. Zhang, H. Ni, Y. Ding, and W. Yuan, "Study on characteristics of moisture diffusion in multi-layer paper insulation," IEEE 19th International Conference on Dielectric Liquids (ICDL), Manchester, UK. pp. 1-4, Jun. 2017.
[CrossRef] [SCOPUS Times Cited 4]


[19] D. Wang, L. Zhou, A. Wang, H. Li, and W. Liao, "Effects of thermal aging on moisture diffusion in insulation paper immersed with mineral oil," IEEE Trans. Dielectr. Electr. Insul., vol. 25(5), pp. 1888-1896, Jun. 2018.
[CrossRef] [Web of Science Times Cited 24] [SCOPUS Times Cited 29]


[20] L. Zhou, W. Liao, Y. Wang, D. Wang, G. Zhang, Y. Cui, and et al., "A high-precision diagnosis method for damp status of OIP bushing," IEEE Trans. Instrum. Meas., vol. 70. Jun. 2021.
[CrossRef] [Web of Science Times Cited 10] [SCOPUS Times Cited 14]


[21] D. Wang, L. Zhou, Z. Yang, W. Liao, L. Wang, and L. Guo, "Simulation for transient moisture distribution and effects on the electric field in stable condition: 110 kV oil-immersed insulation paper bushing," IEEE Access, vol.7, pp. 162991-163002, Nov. 2019.
[CrossRef] [Web of Science Times Cited 9] [SCOPUS Times Cited 11]


[22] Q. Liu, "Electrical insulation design principles," Beijing, China: Machinery Industry Press. 1988

[23] J. K. Kim, S. C. Hahn, K. Y. Park, K. K. Hong, and Y. H. Oh, "Temperature rise prediction of EHV GIS bus bar by coupled magnetothermal finite element method," IEEE Trans. Magn., vol. 41(5), pp. 1636-1639, May. 2005.
[CrossRef] [Web of Science Times Cited 59]


[24] Y. Zhang, J. Ruan, H. Tao, X. Yang, H. Zhu, and Y. Gao, "Calculation of temperature rise in air-cooled induction motors through 3-D coupled electromagnetic fluid-dynamical and thermal finite-element analysis," IEEE Trans. Magn., vol. 48(8), pp. 81047-1050, Feb. 2012.
[CrossRef] [Web of Science Times Cited 88] [SCOPUS Times Cited 144]


[25] M. B. Eteiba, M. M. Aziz, and J. H. Shazly, "Heat conduction problems in SF6 gas cooled-insulated power transformers solved by the finite-element method," IEEE Trans. Power Delivery, vol. 23(3), pp. 1457-1463, Jul. 2008.
[CrossRef] [Web of Science Times Cited 14] [SCOPUS Times Cited 39]


[26] Q. Wang, J. Liao, H. Tian, L. Peng, and Z. Peng, "Regularity analysis of the temperature distribution of epoxy impregnated paper converter transformer bushings," IEEE Trans. Dielectr. Electr. Insul.,vol. 24(5), pp. 3254-3264, Oct. 2017.
[CrossRef] [Web of Science Times Cited 35] [SCOPUS Times Cited 44]


[27] P. Sujit and D. L. Francisco, "Heat-transfer model for toroidal transformers," IEEE Trans. Power Delivery, vol. 27(2), pp. 813-820, Apr. 2012.
[CrossRef] [Web of Science Times Cited 23] [SCOPUS Times Cited 45]


[28] V. Sarfi, S. Mohajeryami, and A. Majzoobi, "Estimation of water content in a power transformer using moisture dynamic measurement of its oil," High Voltage, vol. 2(1), pp. 11-16, Mar. 2017.
[CrossRef] [Web of Science Times Cited 25] [SCOPUS Times Cited 40]


[29] R. Villarroel, D. F. Garcia, B. Garcia and J. C. Burgos, "Diffusion coefficient in transformer pressboard insulation. Part 1: Non impregnated pressboard," IEEE Trans. Dielectr. Electr. Insul., vol. 21(1), pp. 360-368, Feb. 2014.
[CrossRef] [Web of Science Times Cited 10] [SCOPUS Times Cited 16]


[30] Insulating liquids. Oil-impregnated paper and pressboard. Determination of water content by automatic coulometric Karl Fisher titration, IEC Standard 60814:2014



References Weight

Web of Science® Citations for all references: 842 TCR
SCOPUS® Citations for all references: 1,311 TCR

Web of Science® Average Citations per reference: 27 ACR
SCOPUS® Average Citations per reference: 42 ACR

TCR = Total Citations for References / ACR = Average Citations per Reference

We introduced in 2010 - for the first time in scientific publishing, the term "References Weight", as a quantitative indication of the quality ... Read more

Citations for references updated on 2024-06-30 11:23 in 175 seconds.




Note1: Web of Science® is a registered trademark of Clarivate Analytics.
Note2: SCOPUS® is a registered trademark of Elsevier B.V.
Disclaimer: All queries to the respective databases were made by using the DOI record of every reference (where available). Due to technical problems beyond our control, the information is not always accurate. Please use the CrossRef link to visit the respective publisher site.

Copyright ©2001-2024
Faculty of Electrical Engineering and Computer Science
Stefan cel Mare University of Suceava, Romania


All rights reserved: Advances in Electrical and Computer Engineering is a registered trademark of the Stefan cel Mare University of Suceava. No part of this publication may be reproduced, stored in a retrieval system, photocopied, recorded or archived, without the written permission from the Editor. When authors submit their papers for publication, they agree that the copyright for their article be transferred to the Faculty of Electrical Engineering and Computer Science, Stefan cel Mare University of Suceava, Romania, if and only if the articles are accepted for publication. The copyright covers the exclusive rights to reproduce and distribute the article, including reprints and translations.

Permission for other use: The copyright owner's consent does not extend to copying for general distribution, for promotion, for creating new works, or for resale. Specific written permission must be obtained from the Editor for such copying. Direct linking to files hosted on this website is strictly prohibited.

Disclaimer: Whilst every effort is made by the publishers and editorial board to see that no inaccurate or misleading data, opinions or statements appear in this journal, they wish to make it clear that all information and opinions formulated in the articles, as well as linguistic accuracy, are the sole responsibility of the author.




Website loading speed and performance optimization powered by: 


DNS Made Easy