Click to open the HelpDesk interface
AECE - Front page banner

Menu:


FACTS & FIGURES

JCR Impact Factor: 0.700
JCR 5-Year IF: 0.700
SCOPUS CiteScore: 1.8
Issues per year: 4
Current issue: Aug 2024
Next issue: Nov 2024
Avg review time: 59 days
Avg accept to publ: 60 days
APC: 300 EUR


PUBLISHER

Stefan cel Mare
University of Suceava
Faculty of Electrical Engineering and
Computer Science
13, Universitatii Street
Suceava - 720229
ROMANIA

Print ISSN: 1582-7445
Online ISSN: 1844-7600
WorldCat: 643243560
doi: 10.4316/AECE


TRAFFIC STATS

2,983,878 unique visits
1,157,734 downloads
Since November 1, 2009



Robots online now
bingbot
Googlebot


SCOPUS CiteScore

SCOPUS CiteScore


SJR SCImago RANK

SCImago Journal & Country Rank




TEXT LINKS

Anycast DNS Hosting
MOST RECENT ISSUES

 Volume 24 (2024)
 
     »   Issue 3 / 2024
 
     »   Issue 2 / 2024
 
     »   Issue 1 / 2024
 
 
 Volume 23 (2023)
 
     »   Issue 4 / 2023
 
     »   Issue 3 / 2023
 
     »   Issue 2 / 2023
 
     »   Issue 1 / 2023
 
 
 Volume 22 (2022)
 
     »   Issue 4 / 2022
 
     »   Issue 3 / 2022
 
     »   Issue 2 / 2022
 
     »   Issue 1 / 2022
 
 
 Volume 21 (2021)
 
     »   Issue 4 / 2021
 
     »   Issue 3 / 2021
 
     »   Issue 2 / 2021
 
     »   Issue 1 / 2021
 
 
  View all issues  








LATEST NEWS

2024-Jun-20
Clarivate Analytics published the InCites Journal Citations Report for 2023. The InCites JCR Impact Factor of Advances in Electrical and Computer Engineering is 0.700 (0.700 without Journal self-cites), and the InCites JCR 5-Year Impact Factor is 0.600.

2023-Jun-28
Clarivate Analytics published the InCites Journal Citations Report for 2022. The InCites JCR Impact Factor of Advances in Electrical and Computer Engineering is 0.800 (0.700 without Journal self-cites), and the InCites JCR 5-Year Impact Factor is 1.000.

2023-Jun-05
SCOPUS published the CiteScore for 2022, computed by using an improved methodology, counting the citations received in 2019-2022 and dividing the sum by the number of papers published in the same time frame. The CiteScore of Advances in Electrical and Computer Engineering for 2022 is 2.0. For "General Computer Science" we rank #134/233 and for "Electrical and Electronic Engineering" we rank #478/738.

2022-Jun-28
Clarivate Analytics published the InCites Journal Citations Report for 2021. The InCites JCR Impact Factor of Advances in Electrical and Computer Engineering is 0.825 (0.722 without Journal self-cites), and the InCites JCR 5-Year Impact Factor is 0.752.

2022-Jun-16
SCOPUS published the CiteScore for 2021, computed by using an improved methodology, counting the citations received in 2018-2021 and dividing the sum by the number of papers published in the same time frame. The CiteScore of Advances in Electrical and Computer Engineering for 2021 is 2.5, the same as for 2020 but better than all our previous results.

Read More »


    
 

  3/2023 - 2

Electrical Evaluation of Oil-Immersed Power Transformers Based on Temporal Variations in Performance Index and Reliability

DIAS, Y. See more information about DIAS, Y. on SCOPUS See more information about DIAS, Y. on IEEExplore See more information about DIAS, Y. on Web of Science, MARQUES, A. See more information about  MARQUES, A. on SCOPUS See more information about  MARQUES, A. on SCOPUS See more information about MARQUES, A. on Web of Science, RIBEIRO, C. See more information about  RIBEIRO, C. on SCOPUS See more information about  RIBEIRO, C. on SCOPUS See more information about RIBEIRO, C. on Web of Science, BRITO, L. See more information about BRITO, L. on SCOPUS See more information about BRITO, L. on SCOPUS See more information about BRITO, L. on Web of Science
 
Extra paper information in View the paper record and citations in Google Scholar View the paper record and similar papers in Microsoft Bing View the paper record and similar papers in Semantic Scholar the AI-powered research tool
Click to see author's profile in See more information about the author on SCOPUS SCOPUS, See more information about the author on IEEE Xplore IEEE Xplore, See more information about the author on Web of Science Web of Science

Download PDF pdficon (1,408 KB) | Citation | Downloads: 613 | Views: 1,074

Author keywords
condition monitoring, failure analysis, maintenance engineering, power transformers, reliability engineering

References keywords
power(13), transformers(12), insulation(10), analysis(7), interpretation(5), insulating(5), marques(4), guide(4), dielectric(4), dias(4)
Blue keywords are present in both the references section and the paper title.

About this article
Date of Publication: 2023-08-31
Volume 23, Issue 3, Year 2023, On page(s): 13 - 20
ISSN: 1582-7445, e-ISSN: 1844-7600
Digital Object Identifier: 10.4316/AECE.2023.03002
Web of Science Accession Number: 001062641900002
SCOPUS ID: 85172334203

Abstract
Quick view
Full text preview
In electrical systems, power transformer failure prediction is a strategic procedure aimed at ensuring the uninterrupted delivery of electricity. In this context, companies of electricity employ predictive maintenance techniques to evaluate the status of this type of equipment. Aiming to contribute by adding monitoring criteria and complementing research in this field, to help maintenance teams project the future status of their power transformers immersed in insulating mineral oil with nominal voltages rated from 34.5 kV to 230 kV and above, with powers from tens to hundreds of MVA, and with and without on-load tap changer, this article presents an innovative method for projection the performance index of these assets on any given date, and to obtain a numerically reliability projection for that date. The originality of this tool stems from its combined use of two easy-to-implement mathematical criteria, considering the historical results of current and previous maintenance dielectric and electrical tests: the Weighted Moving Average and the Consistency of the Historical Neighborhood. Thus, this method is expected to contribute to more accurate to decisions making by maintenance teams.


References | Cited By  «-- Click to see who has cited this paper

[1] N. Chakraborty, S. W. Human, N. Balakrishnan, "A generally weighted moving average chart for time between events," Communications in Statistics - Simulation and Computation, 46:10, 7790-7817, 2017.
[CrossRef] [Web of Science Times Cited 31] [SCOPUS Times Cited 32]


[2] M. B. Perry, "The weighted moving average technique," Wiley Encyclopedia of Operations Research and Management Science, 2010.
[CrossRef]


[3] X. Su, X. Yan, and C. Tsai, "Linear regression," Wiley Interdisciplinary Reviews: Computational Statistics 4.3, pp. 275-294, 2012.
[CrossRef] [Web of Science Times Cited 196] [SCOPUS Times Cited 268]


[4] S. Weisberg, "Applied linear regression," John Wiley & Sons, 2013,
[CrossRef] [SCOPUS Times Cited 1397]


[5] Institute of Electrical and Electronics Engineers, "IEEE Std C57.152-2013 - IEEE guide for diagnostic field testing of fluid-filled power transformers, regulators, and reactors," New York: IEEE, 2013.
[CrossRef]


[6] Institute of Electrical and Electronics Engineers, "IEEE C57.125-2015 - IEEE Guide for Failure Investigation, Documentation, and Analysis for Power Transformers and Shunt Reactors," New York: IEEE, 2015.
[CrossRef]


[7] M. Mandlik, and T. S. Ramu, "Moisture aided degradation of oil impregnated paper insulation in power transformers," IEEE Transactions on Dielectrics and Electrical Insulation, 21.1, pp. 186-193, 2014.
[CrossRef] [Web of Science Times Cited 48] [SCOPUS Times Cited 61]


[8] P. J. Baird, H. Herman, G. C. Steven,s and P. N. Jarman, "Non-destructive measurement of the degradation of transformer insulating paper," IEEE Transactions on Dielectrics and Electrical Insulation, 13(2), pp. 309-318, 2006.
[CrossRef] [Web of Science Times Cited 51] [SCOPUS Times Cited 71]


[9] X. Chendong, "Monitoring paper insulation ageing by measuring furfural contents in oil," in 7th Int. Symp. on High Voltage Eng., pp. 26-30, 1991

[10] L. Cheim, D. Platts, T. Prevost, S. Xu, "Furan analysis for liquid power transformers," Electrical Insulation Magazine, IEEE, vol. 28, pp.8-21, 2012.
[CrossRef]


[11] R. D. Stebbins, D. S. Myers, A. B. Shkolnik, "Furanic compounds in dielectric liquid samples: Review and update of diagnostic interpretation and estimation of insulation ageing," in 7th Int. Conf. on Properties and Appl. of Dielectr. Mater., pp. 921-926, 2003.
[CrossRef]


[12] A. de Pablo, Interpretation of furanic compounds analysis degradation models, CIGRE, 1997

[13] A. de Pablo, "Furfural and ageing: How are they related," In IEEE Colloquium on Insulating Liquids, pp. 5/1-5/4, 1999.
[CrossRef]


[14] A. J. Kachler and I. Hohlein, "Aging of cellulose at transformer service temperatures. Part 1: Influence of type of oil and air on the degree of polymerization of pressboard, dissolved gases and furanic compounds in oil," IEEE Electr. Insul. Mag., vol. 21(2), pp. 15- 21, 2005.
[CrossRef] [Web of Science Times Cited 97] [SCOPUS Times Cited 131]


[15] A. B. Shkolnik, R. T. Rasor and S. D. Myers, "Statistical insights into furan interpretation using a large dielectric fluid testing database," in IEEE PES Transmission and Distribution Conf. and Expo., pp. 1-8, 2012.
[CrossRef] [SCOPUS Times Cited 21]


[16] M. K. Pradhan, T. S. Ramu, "On the estimation of elapsed life of oil-immersed power transformers," IEEE Trans. Power Del., vol. 20(3), pp. 1962-1969, 2005.
[CrossRef] [Web of Science Times Cited 85] [SCOPUS Times Cited 126]


[17] T. K. Saha, "Review of modern diagnostic techniques for assessing insulation condition in aged transformers," IEEE Transaction on Dielectrics and Electrical insulation, vol. 10, No. 5, Oct. 2003.
[CrossRef] [Web of Science Times Cited 500] [SCOPUS Times Cited 739]


[18] F. Ortiz, C. Fernandez-Diego, A. Santisteban, F. Delgado, A. Ortiz, "Estimating the age of power transformers using the concentration of furans in dielectric oil," Renewable Energy and Power Quality Journal, No. 14, May 2016.
[CrossRef] [SCOPUS Times Cited 16]


[19] D. Kanumuri, V. Sharma, and O. P. Rahi, "Analysis using various approaches for residual life estimation of power transformers," International Journal on Electrical Engineering and Informatics - Volume 11, Number 2, Jun. 2019.
[CrossRef] [SCOPUS Times Cited 16]


[20] A. P. Marques, "Optimized diagnosis of power transformers through the integration of predictive techniques," Thesis (PhD in Electrical and Computation Engineering) - School of Electrical, Mechanical and Computer Engineering, Federal University of Goias, Goiania, Brazil 2018

[21] A. Marques, N. K. Moura, Y. A. Dias, C. J. Ribeiro, A. S. Rocha, L. da C. Brito, C. H. B. Azevedo, and J. A. L. Santos, "Method for the evaluation and classification of power transformer insulating oil based on physicochemical analyses," in IEEE Electrical Insulation Magazine, vol. 33, no. 1, pp. 39-49, January-February 2017.
[CrossRef] [SCOPUS Times Cited 11]


[22] A. P. Marques, N. K. Moura, C. J. Ribeiro, Y. A. Dias, A. Rodrigues, A. S. Rocha, C. H. B. Azevedo, J. A. L. Santos, F. de C. Sousa, and L. da C. Brito, "Insulation resistance of power transformers - Method for optimized analysis," in Proc. 19th IEEE International Conference on Dielectric Liquids - ICDL. Manchester, United Kingdom, June 2017.
[CrossRef] [SCOPUS Times Cited 7]


[23] Institute of Electrical and Electronics Engineers, "IEEE Std C57.104-2019," IEEE Guide for the Interpretation of Gases Generated in Oil-immersed Transformers, New York, 2019.
[CrossRef]


[24] International Electrotechnical Commission, IEC 60599:2015, "Mineral oil-impregnated electrical equipament in service - Guide to the interpretation of dissolved and free gases analysis,", 2015

[25] L. C. Brito, A. P. Marques, C. J. Ribeiro, A. S. Rocha, Y. A. Dias, N. K. Moura, P. H. S. Palhares, C. H. B. Azevedo, and J. A. L. Santos, "Combined approach of the IEEE and IEC guides for interpreting dissolved gas analysis in insulating mineral oil," in Proc. VI Brazilian Symposium on Electrical Systems, Natal, May, pp. 1-6, 2016

[26] Y. A. Dias, "Bayesian network for estimating the reliability of power transformers immersed in insulating mineral oil using predictive maintenance techniques," Dissertation. MSc in Electrical and Computation Engineering - Federal University of Goias, Goiania, Brazil, 2019



References Weight

Web of Science® Citations for all references: 1,008 TCR
SCOPUS® Citations for all references: 2,896 TCR

Web of Science® Average Citations per reference: 37 ACR
SCOPUS® Average Citations per reference: 107 ACR

TCR = Total Citations for References / ACR = Average Citations per Reference

We introduced in 2010 - for the first time in scientific publishing, the term "References Weight", as a quantitative indication of the quality ... Read more

Citations for references updated on 2024-11-14 10:31 in 149 seconds.




Note1: Web of Science® is a registered trademark of Clarivate Analytics.
Note2: SCOPUS® is a registered trademark of Elsevier B.V.
Disclaimer: All queries to the respective databases were made by using the DOI record of every reference (where available). Due to technical problems beyond our control, the information is not always accurate. Please use the CrossRef link to visit the respective publisher site.

Copyright ©2001-2024
Faculty of Electrical Engineering and Computer Science
Stefan cel Mare University of Suceava, Romania


All rights reserved: Advances in Electrical and Computer Engineering is a registered trademark of the Stefan cel Mare University of Suceava. No part of this publication may be reproduced, stored in a retrieval system, photocopied, recorded or archived, without the written permission from the Editor. When authors submit their papers for publication, they agree that the copyright for their article be transferred to the Faculty of Electrical Engineering and Computer Science, Stefan cel Mare University of Suceava, Romania, if and only if the articles are accepted for publication. The copyright covers the exclusive rights to reproduce and distribute the article, including reprints and translations.

Permission for other use: The copyright owner's consent does not extend to copying for general distribution, for promotion, for creating new works, or for resale. Specific written permission must be obtained from the Editor for such copying. Direct linking to files hosted on this website is strictly prohibited.

Disclaimer: Whilst every effort is made by the publishers and editorial board to see that no inaccurate or misleading data, opinions or statements appear in this journal, they wish to make it clear that all information and opinions formulated in the articles, as well as linguistic accuracy, are the sole responsibility of the author.




Website loading speed and performance optimization powered by: 


DNS Made Easy