Click to open the HelpDesk interface
AECE - Front page banner

Menu:


FACTS & FIGURES

JCR Impact Factor: 0.700
JCR 5-Year IF: 0.700
SCOPUS CiteScore: 1.8
Issues per year: 4
Current issue: Aug 2024
Next issue: Nov 2024
Avg review time: 59 days
Avg accept to publ: 60 days
APC: 300 EUR


PUBLISHER

Stefan cel Mare
University of Suceava
Faculty of Electrical Engineering and
Computer Science
13, Universitatii Street
Suceava - 720229
ROMANIA

Print ISSN: 1582-7445
Online ISSN: 1844-7600
WorldCat: 643243560
doi: 10.4316/AECE


TRAFFIC STATS

2,984,624 unique visits
1,157,955 downloads
Since November 1, 2009



Robots online now
SemrushBot


SCOPUS CiteScore

SCOPUS CiteScore


SJR SCImago RANK

SCImago Journal & Country Rank




TEXT LINKS

Anycast DNS Hosting
MOST RECENT ISSUES

 Volume 24 (2024)
 
     »   Issue 3 / 2024
 
     »   Issue 2 / 2024
 
     »   Issue 1 / 2024
 
 
 Volume 23 (2023)
 
     »   Issue 4 / 2023
 
     »   Issue 3 / 2023
 
     »   Issue 2 / 2023
 
     »   Issue 1 / 2023
 
 
 Volume 22 (2022)
 
     »   Issue 4 / 2022
 
     »   Issue 3 / 2022
 
     »   Issue 2 / 2022
 
     »   Issue 1 / 2022
 
 
 Volume 21 (2021)
 
     »   Issue 4 / 2021
 
     »   Issue 3 / 2021
 
     »   Issue 2 / 2021
 
     »   Issue 1 / 2021
 
 
  View all issues  




SAMPLE ARTICLES

A Novel Control Approach Utilizing Neural Network for Efficient Microgrid Operation with Solar PV and Energy Storage Systems, JABBARI, A., KHAN, H., MUSHTAQ, D., SARWAR, M., DURAIBI, S., ALMALKI, K. J., AHMED, W., SIDDIQUI, A. S.
Issue 3/2024

AbstractPlus

A Novel Approach for Knowledge Discovery from AIS Data: An Application for Transit Marine Traffic in the Sea of Marmara, DOGAN, Y., KART, O., KUNDAKCI, B., NAS, S.
Issue 3/2021

AbstractPlus

On Board Neuro Fuzzy Inverse Optimal Control for Type 1 Diabetes Mellitus Treatment: In-Silico Testing, RIOS, Y., GARCIA-RODRIGUEZ, J., SANCHEZ, E., ALANIS, A., RUIZ-VELAZQUEZ, E., PARDO-GARCIA, A.
Issue 3/2022

AbstractPlus

Control Based on Linear Matrix Inequalities for Power Converters of an Islanded AC Microgrid, TERAN, R. A. J., PEREZ, J., BERISTAIN, J. A., VALLE, O. A.
Issue 3/2022

AbstractPlus

Lossy Compression using Adaptive Polynomial Image Encoding, OTHMAN, S., MOHAMED, A., ABOUALI, A., NOSSAIR, Z.
Issue 1/2021

AbstractPlus

Analog Circuit Fault Classification and Data Reduction Using PCA-ANFIS Technique Aided by K-means Clustering Approach, LAIDANI, I., BOUROUBA, N.
Issue 4/2022

AbstractPlus




LATEST NEWS

2024-Jun-20
Clarivate Analytics published the InCites Journal Citations Report for 2023. The InCites JCR Impact Factor of Advances in Electrical and Computer Engineering is 0.700 (0.700 without Journal self-cites), and the InCites JCR 5-Year Impact Factor is 0.600.

2023-Jun-28
Clarivate Analytics published the InCites Journal Citations Report for 2022. The InCites JCR Impact Factor of Advances in Electrical and Computer Engineering is 0.800 (0.700 without Journal self-cites), and the InCites JCR 5-Year Impact Factor is 1.000.

2023-Jun-05
SCOPUS published the CiteScore for 2022, computed by using an improved methodology, counting the citations received in 2019-2022 and dividing the sum by the number of papers published in the same time frame. The CiteScore of Advances in Electrical and Computer Engineering for 2022 is 2.0. For "General Computer Science" we rank #134/233 and for "Electrical and Electronic Engineering" we rank #478/738.

2022-Jun-28
Clarivate Analytics published the InCites Journal Citations Report for 2021. The InCites JCR Impact Factor of Advances in Electrical and Computer Engineering is 0.825 (0.722 without Journal self-cites), and the InCites JCR 5-Year Impact Factor is 0.752.

2022-Jun-16
SCOPUS published the CiteScore for 2021, computed by using an improved methodology, counting the citations received in 2018-2021 and dividing the sum by the number of papers published in the same time frame. The CiteScore of Advances in Electrical and Computer Engineering for 2021 is 2.5, the same as for 2020 but better than all our previous results.

Read More »


    
 

  3/2022 - 3

A Protection Strategy for MV Distribution Networks with Embedded Inverter-based DGs

SOLEIMANISARDOO, A. See more information about SOLEIMANISARDOO, A. on SCOPUS See more information about SOLEIMANISARDOO, A. on IEEExplore See more information about SOLEIMANISARDOO, A. on Web of Science, KAZEMI-KAREGAR, H. See more information about KAZEMI-KAREGAR, H. on SCOPUS See more information about KAZEMI-KAREGAR, H. on SCOPUS See more information about KAZEMI-KAREGAR, H. on Web of Science
 
Extra paper information in View the paper record and citations in Google Scholar View the paper record and similar papers in Microsoft Bing View the paper record and similar papers in Semantic Scholar the AI-powered research tool
Click to see author's profile in See more information about the author on SCOPUS SCOPUS, See more information about the author on IEEE Xplore IEEE Xplore, See more information about the author on Web of Science Web of Science

Download PDF pdficon (1,277 KB) | Citation | Downloads: 583 | Views: 1,558

Author keywords
distributed power generation, inverter, power distribution faults, power system protection, PSCAD

References keywords
power(24), protection(17), distributed(15), generation(13), distribution(12), inverter(10), systems(9), energy(9), fault(8), scheme(7)
Blue keywords are present in both the references section and the paper title.

About this article
Date of Publication: 2022-08-31
Volume 22, Issue 3, Year 2022, On page(s): 25 - 32
ISSN: 1582-7445, e-ISSN: 1844-7600
Digital Object Identifier: 10.4316/AECE.2022.03003
Web of Science Accession Number: 000861021000003
SCOPUS ID: 85137694601

Abstract
Quick view
Full text preview
Despite the many benefits of Distributed Generations (DGs), they can cause mis-coordination between protective devices by changes in the fault current level. Many DGs are connected to the network through power electronic (PE) interfaces, which are called Inverter Based Distributed Generators (IBDGs). This paper proposes a new method to mitigate the impact of IBDGs on existing protection coordination. The method manages IBDG fault current contribution by their PE interfaces in such a way that the digital protective devices can distinguish and ignore it. In addition, the fuse-recloser coordination in presence of DG is investigated and it is shown that the proposed method is able to preserve the original fuse-recloser coordination after installing IBDGs. The method does not require any communication infrastructure and is independent of penetration level and location of IBDGs and supports the plug and play functionality of IBDGs. The effectiveness of the proposed method is verified by simulation results on the IEEE 33-Bus power system with PSCAD/EMTDC software.


References | Cited By  «-- Click to see who has cited this paper

[1] A. An, B. Zheng, H. Zheng, C. Zheng and P. Du, "Benefit analysis and evaluation of distributed generation in distribution network under active management," 2016 Chinese Control and Decision Conference (CCDC), 2016, pp. 6031-6035,
[CrossRef] [SCOPUS Times Cited 6]


[2] L. Mehigan, J. P. Deane, B. P. O. Gallachoir, V. Bertsch, "A review of the role of distributed generation (DG) in future electricity systems," Energy, vol. 163, pp. 822-836, 2018.
[CrossRef] [Web of Science Times Cited 136] [SCOPUS Times Cited 188]


[3] H. A. Gil, G. Joos, "Models for quantifying the economic benefits of distributed generation," IEEE Trans. Power Systems, vol. 23, pp. 327-335, 2008.
[CrossRef] [Web of Science Times Cited 131] [SCOPUS Times Cited 168]


[4] S. Conti, "Protection issues and state of the art for microgrid with inverter interfaced distributed generators," in International Conference on Clean Electrical Power (ICCEP), Italy, 2011, pp. 643-647.
[CrossRef] [SCOPUS Times Cited 14]


[5] L. Huchel, H. Zeineldin, E. El-Saadany, "Protection coordination index enhancement considering multiple DG locations using FCL," IEEE Trans. Power Delivery, vol. 32, pp. 344-350, 2017.
[CrossRef] [Web of Science Times Cited 37] [SCOPUS Times Cited 47]


[6] A. Soleimanisardoo, H. K. Karegar, "Alleviating the impact of DGs and network operation modes on the protection system," IET Generation, Transmission & Distribution, vol. 14, pp. 21-28, 2020.
[CrossRef] [Web of Science Times Cited 5] [SCOPUS Times Cited 6]


[7] B. Kroposki, B. Johnson, Y. Zhang, V. Gevorgian, P. Denholm, P. Hodge, B. Hannegan, "Achieving a 100% renewable grid: Operating electric power systems with extremely high levels of variable renewable energy," IEEE Power and Energy Magazine, vol. 15, pp. 61-73, 2017.
[CrossRef] [Web of Science Times Cited 761] [SCOPUS Times Cited 1023]


[8] V. Telukunta, J. Pradhan, A. Agrawal, M. Singh, S. G. Srivani, "Protection challenges under bulk penetration of renewable energy resources in power systems: A review," Journal of Power and Energy Systems, vol. 3, pp. 365-379, 2017.
[CrossRef] [Web of Science Times Cited 761] [SCOPUS Times Cited 1023]


[9] N. Rajaei, M. H. Ahmed, M. M A. Salama, K. Varma, "Fault current management using inverter-based distributed generators in smart grids," IEEE Trans. Smart Grid, vol. 5, pp. 2183-2193, 2014.
[CrossRef] [Web of Science Times Cited 48] [SCOPUS Times Cited 58]


[10] K. Wheeler, M. Elsamahy, F. Faried, "Use of superconducting fault current limiters for mitigation of distributed generation influences in radial distribution network fuse-recloser protection systems," IET Generation, Transmission & Distribution, vol. 11, pp. 1605-1612, 2017.
[CrossRef] [Web of Science Times Cited 33] [SCOPUS Times Cited 37]


[11] H. Radmanesh, A. Heidary, S. M. Fathi, G. Babamalek, "Dual function ferroresonance and fault current limiter based on DC reactor," IET Renewable Power Generation, vol. 10, pp. 2058-2065, 2016.
[CrossRef] [Web of Science Times Cited 25] [SCOPUS Times Cited 27]


[12] Y. Zhang, R. A. Dougal, "Novel dual-FCL connection for adding distributed generation to a power distribution utility," IEEE Trans. Appl. Supercond., vol. 21, pp. 2179-2183, 2011.
[CrossRef] [Web of Science Times Cited 21] [SCOPUS Times Cited 30]


[13] H. Yazdanpanahi, H. Li, W. Xu, "A new control strategy to mitigate the impact of inverter-based DGs on protection system," IEEE Trans. Smart Grid, vol. 3, pp. 1427-1436, 2012.
[CrossRef] [Web of Science Times Cited 148] [SCOPUS Times Cited 173]


[14] E. Casagrande, W. L. Woon, H. H. Zeineldin and D. Svetinovic, "A differential sequence component protection scheme for microgrids with inverter-based distributed generators," IEEE Transactions on Smart Grid, vol. 5, pp. 29-37, 2014.
[CrossRef] [Web of Science Times Cited 188] [SCOPUS Times Cited 227]


[15] S. Kar, S. R. Samantaray, "Time-frequency transform-based differential scheme for microgrid protection," IET Generation, Transmission & Distribution, vol. 8, pp. 310-320, 2014.
[CrossRef] [Web of Science Times Cited 170] [SCOPUS Times Cited 213]


[16] W. Huang, T. Nengling, X. Zheng, C. Fan, X. Yang, B. J. Kirby, "An impedance protection scheme for feeders of active distribution networks," IEEE Transactions on Power Delivery, vol. 29, pp. 1591-1602, 2014.
[CrossRef] [Web of Science Times Cited 80] [SCOPUS Times Cited 98]


[17] A. Soleimanisardoo, H. K. Karegar, H. H Zeineldin, "Differential frequency protection scheme based on off-nominal frequency injections for inverter-based islanded microgrids," IEEE Trans. Smart Grid, vol. 10, pp. 2107-2114. 2019.
[CrossRef] [Web of Science Times Cited 74] [SCOPUS Times Cited 100]


[18] E. Sortomme, S. S. Venkata, J. Mitra, "Microgrid protection using communication-assisted digital relays," IEEE Trans. Power Del., vol. 25, pp. 2789-2796, 2010.
[CrossRef] [Web of Science Times Cited 388] [SCOPUS Times Cited 513]


[19] M. Singh, T. Vishnuvardhan, S. G. Srivani, "Adaptive protection coordination scheme for power networks under penetration of distributed energy resources," IET Generation, Transmission & Distribution, vol. 10, pp. 3919-3929, 2016.
[CrossRef] [Web of Science Times Cited 82] [SCOPUS Times Cited 93]


[20] V. Papaspiliotopoulos, G. Korres, V. Kleftakis, N. Hatziargyriou, "Hardware-in-the-loop design and optimal setting of adaptive protection schemes for distribution systems with distributed," IEEE Trans. Power Delivery, vol. 32, pp. 393-400, 2017.
[CrossRef] [Web of Science Times Cited 123] [SCOPUS Times Cited 149]


[21] Z. Liu, C. Su, H. K. Hoidalen, Z. Chen, "A Multi-agent system based protection and control scheme for distribution system with distributed generation integration," IEEE Trans. Power Delivery, vol. 32, pp. 536-545, 2017.
[CrossRef] [Web of Science Times Cited 92] [SCOPUS Times Cited 109]


[22] F. Coffele, C. Booth, A. Dysko, "An adaptive overcurrent protection scheme for distribution networks," IEEE Trans. Power Delivery, vol. 30, pp. 561-568, 2015.
[CrossRef] [Web of Science Times Cited 209] [SCOPUS Times Cited 282]


[23] P. T. Manditereza, R. Bansal, "Renewable distributed generation. The hidden challenge-A review from the protection perspective," Renewable and Sustainable Energy Reviews, vol. 58, pp. 1457-1465, 2016.
[CrossRef] [Web of Science Times Cited 163] [SCOPUS Times Cited 210]


[24] I. Sadeghkhani, M. E. H. Golshan, J. M. Guerrero, A. Mehrizi-Sani, "A current limiting strategy to improve fault ride-through of inverter interfaced autonomous microgrids," IEEE Trans. Smart Grid, vol. 8, pp. 2138-2148, 2017.
[CrossRef] [Web of Science Times Cited 147] [SCOPUS Times Cited 175]


[25] X. Pei, Y. Kang, "Short-circuit fault protection strategy for high power three-phase three-wire inverter," IEEE Transactions on Industrial Informatics, vol. 8, pp. 545-553, 2012.
[CrossRef] [Web of Science Times Cited 66] [SCOPUS Times Cited 73]


[26] C. Plet, M. Graovac, T. C. Green, R. Iravani, "Fault response of grid-connected inverter dominated networks," in IEEE Power and Energy Society General Meeting, USA, 2010, pp. 25-29.
[CrossRef] [SCOPUS Times Cited 158]


[27] N. Bottrell, T. C. Green, "Comparison of current-limiting strategies during fault ride-through of inverters to prevent latch-up and wind-up," IEEE Trans. Power Electron, vol. 29, pp. 3786-3797, 2014.
[CrossRef] [Web of Science Times Cited 186] [SCOPUS Times Cited 236]


[28] M. M. Zamani, A. Yazdani, T. S. Sidhu, "A control strategy for enhanced operation of inverter-based microgrids under transient disturbances and network faults," IEEE Trans. Power Deliver, vol. 27, pp. 1737-1747. 2012.
[CrossRef] [Web of Science Times Cited 186] [SCOPUS Times Cited 236]


[29] Z. Shuai, C. Shen, X. Yin, X. Liu, Z. J. Shen, "Fault analysis of inverter-interfaced distributed generators with different control schemes," IEEE Transactions on Power Delivery, vol. 3, pp. 1223-1235, 2018.
[CrossRef] [Web of Science Times Cited 174] [SCOPUS Times Cited 232]


[30] S. Chaitusaney, A. Yokoyama, "Prevention of reliability degradation from recloser - fuse miscoordination due to distributed generation," IEEE Trans. Power Delivery, vol. 23, pp. 2545-2554, 2008.
[CrossRef] [Web of Science Times Cited 140] [SCOPUS Times Cited 170]


[31] "IEEE Guide for the Operation, Classification, Application, and Coordination of Current-Limiting Fuses with Rated Voltages 1-38 kV," in IEEE Std C37.48.1-2002 , vol., no., pp.1-68, 6 Aug. 2002, (R.2008).
[CrossRef]


[32] H. Li, F. Li, Y. Xu, D. T. Rizy, J. D. Kueck, "Adaptive voltage control with distributed energy resources: Algorithm, theoretical analysis, simulation, and field test verification," IEEE Trans. Power Systems, vol. 25, pp. 1638-1647, 2010.
[CrossRef] [Web of Science Times Cited 127] [SCOPUS Times Cited 162]


[33] S. H. Horowitz, A. G. Phadk, Power system relaying. Wiley & Sons, New York, 1992

[34] B. Venkatesh, R. Ranjan, H. B. Gooi, "Optimal reconfiguration of radial distribution networks to maximize load ability," IEEE Transactions on Power Systems, vol. 19, pp.260-266, 2004.
[CrossRef] [Web of Science Times Cited 247] [SCOPUS Times Cited 330]




References Weight

Web of Science® Citations for all references: 4,948 TCR
SCOPUS® Citations for all references: 6,566 TCR

Web of Science® Average Citations per reference: 141 ACR
SCOPUS® Average Citations per reference: 188 ACR

TCR = Total Citations for References / ACR = Average Citations per Reference

We introduced in 2010 - for the first time in scientific publishing, the term "References Weight", as a quantitative indication of the quality ... Read more

Citations for references updated on 2024-11-16 16:56 in 221 seconds.




Note1: Web of Science® is a registered trademark of Clarivate Analytics.
Note2: SCOPUS® is a registered trademark of Elsevier B.V.
Disclaimer: All queries to the respective databases were made by using the DOI record of every reference (where available). Due to technical problems beyond our control, the information is not always accurate. Please use the CrossRef link to visit the respective publisher site.

Copyright ©2001-2024
Faculty of Electrical Engineering and Computer Science
Stefan cel Mare University of Suceava, Romania


All rights reserved: Advances in Electrical and Computer Engineering is a registered trademark of the Stefan cel Mare University of Suceava. No part of this publication may be reproduced, stored in a retrieval system, photocopied, recorded or archived, without the written permission from the Editor. When authors submit their papers for publication, they agree that the copyright for their article be transferred to the Faculty of Electrical Engineering and Computer Science, Stefan cel Mare University of Suceava, Romania, if and only if the articles are accepted for publication. The copyright covers the exclusive rights to reproduce and distribute the article, including reprints and translations.

Permission for other use: The copyright owner's consent does not extend to copying for general distribution, for promotion, for creating new works, or for resale. Specific written permission must be obtained from the Editor for such copying. Direct linking to files hosted on this website is strictly prohibited.

Disclaimer: Whilst every effort is made by the publishers and editorial board to see that no inaccurate or misleading data, opinions or statements appear in this journal, they wish to make it clear that all information and opinions formulated in the articles, as well as linguistic accuracy, are the sole responsibility of the author.




Website loading speed and performance optimization powered by: 


DNS Made Easy