Click to open the HelpDesk interface
AECE - Front page banner

Menu:


FACTS & FIGURES

JCR Impact Factor: 0.700
JCR 5-Year IF: 0.700
SCOPUS CiteScore: 1.8
Issues per year: 4
Current issue: Aug 2024
Next issue: Nov 2024
Avg review time: 59 days
Avg accept to publ: 60 days
APC: 300 EUR


PUBLISHER

Stefan cel Mare
University of Suceava
Faculty of Electrical Engineering and
Computer Science
13, Universitatii Street
Suceava - 720229
ROMANIA

Print ISSN: 1582-7445
Online ISSN: 1844-7600
WorldCat: 643243560
doi: 10.4316/AECE


TRAFFIC STATS

2,983,030 unique visits
1,157,422 downloads
Since November 1, 2009



Robots online now
bingbot
Googlebot


SCOPUS CiteScore

SCOPUS CiteScore


SJR SCImago RANK

SCImago Journal & Country Rank




TEXT LINKS

Anycast DNS Hosting
MOST RECENT ISSUES

 Volume 24 (2024)
 
     »   Issue 3 / 2024
 
     »   Issue 2 / 2024
 
     »   Issue 1 / 2024
 
 
 Volume 23 (2023)
 
     »   Issue 4 / 2023
 
     »   Issue 3 / 2023
 
     »   Issue 2 / 2023
 
     »   Issue 1 / 2023
 
 
 Volume 22 (2022)
 
     »   Issue 4 / 2022
 
     »   Issue 3 / 2022
 
     »   Issue 2 / 2022
 
     »   Issue 1 / 2022
 
 
 Volume 21 (2021)
 
     »   Issue 4 / 2021
 
     »   Issue 3 / 2021
 
     »   Issue 2 / 2021
 
     »   Issue 1 / 2021
 
 
  View all issues  








LATEST NEWS

2024-Jun-20
Clarivate Analytics published the InCites Journal Citations Report for 2023. The InCites JCR Impact Factor of Advances in Electrical and Computer Engineering is 0.700 (0.700 without Journal self-cites), and the InCites JCR 5-Year Impact Factor is 0.600.

2023-Jun-28
Clarivate Analytics published the InCites Journal Citations Report for 2022. The InCites JCR Impact Factor of Advances in Electrical and Computer Engineering is 0.800 (0.700 without Journal self-cites), and the InCites JCR 5-Year Impact Factor is 1.000.

2023-Jun-05
SCOPUS published the CiteScore for 2022, computed by using an improved methodology, counting the citations received in 2019-2022 and dividing the sum by the number of papers published in the same time frame. The CiteScore of Advances in Electrical and Computer Engineering for 2022 is 2.0. For "General Computer Science" we rank #134/233 and for "Electrical and Electronic Engineering" we rank #478/738.

2022-Jun-28
Clarivate Analytics published the InCites Journal Citations Report for 2021. The InCites JCR Impact Factor of Advances in Electrical and Computer Engineering is 0.825 (0.722 without Journal self-cites), and the InCites JCR 5-Year Impact Factor is 0.752.

2022-Jun-16
SCOPUS published the CiteScore for 2021, computed by using an improved methodology, counting the citations received in 2018-2021 and dividing the sum by the number of papers published in the same time frame. The CiteScore of Advances in Electrical and Computer Engineering for 2021 is 2.5, the same as for 2020 but better than all our previous results.

Read More »


    
 

  1/2021 - 4

Phase-Locked Loop with Inverse Tangent based Phase Detection

STOJIC, D. See more information about STOJIC, D. on SCOPUS See more information about STOJIC, D. on IEEExplore See more information about STOJIC, D. on Web of Science
 
Extra paper information in View the paper record and citations in Google Scholar View the paper record and similar papers in Microsoft Bing View the paper record and similar papers in Semantic Scholar the AI-powered research tool
Click to see author's profile in See more information about the author on SCOPUS SCOPUS, See more information about the author on IEEE Xplore IEEE Xplore, See more information about the author on Web of Science Web of Science

Download PDF pdficon (1,404 KB) | Citation | Downloads: 1,024 | Views: 1,979

Author keywords
estimation, frequency locked loops, nonlinear control systems, phase locked loops, power conversion

References keywords
power(23), electronics(20), phase(17), grid(15), synchronization(14), systems(12), industrial(11), loop(7), locked(5), energy(5)
Blue keywords are present in both the references section and the paper title.

About this article
Date of Publication: 2021-02-28
Volume 21, Issue 1, Year 2021, On page(s): 37 - 44
ISSN: 1582-7445, e-ISSN: 1844-7600
Digital Object Identifier: 10.4316/AECE.2021.01004
Web of Science Accession Number: 000624018800004
SCOPUS ID: 85106415974

Abstract
Quick view
Full text preview
In this paper, a novel closed-loop synchronization algorithm is proposed based on the linear phase angle detection. The linear phase detection is performed by the inverse tangent (atan2) trigonometric function, while the frequency tracking is performed by a proportional-integral (PI) loop filter and phase integrator. By using the linear phase detection, the linear phase-locked loop (PLL) is employed, which is simpler to implement and to tune, and which also performs better for large frequency and phase variations when compared to conventional PLL algorithms. Also, the novel technique operates consistently for a whole range of designated PLL crossover frequencies when compared to existing PLL techniques, which makes it a better candidate when higher filtering is required of higher harmonics and measurement noise. When compared with existing algorithms that use atan function for phase angle estimation, the novel algorithm enables the frequency estimation that does not include differentiation, which improves the resulting algorithm immunity to measurement noise and higher harmonics. The novel PLL is tested by simulation and experimental runs.


References | Cited By  «-- Click to see who has cited this paper

[1] S. Golestan, M. Monfared, F. D. Freijedo, J.M. Guerrero, "Dynamics assessment of advanced single-phase PLL structures," IEEE Transactions on industrial electronics, vol. 60, no. 6, pp. 2167-2177, 2013.
[CrossRef] [Web of Science Times Cited 280] [SCOPUS Times Cited 332]


[2] R. M. Santos Filho, P. F. Seixas, P. C. Cortizo, L. A. Torres, and A. F. Souza, "Comparison of three single-phase PLL algorithms for UPS applications," IEEE Transactions on industrial electronics, vo. 55, no. 8, pp. 2923-2932, 2008.
[CrossRef] [Web of Science Times Cited 357] [SCOPUS Times Cited 433]


[3] F. Baradarani, M. R. D. Zadeh, M. A. Zamani, "A Phase-angle estimation method for synchronization of grid-connected power-electronic converters," IEEE Transactions on Power Delivery, vol. 30, no. 2, pp. 827-835, 2015.
[CrossRef] [Web of Science Times Cited 41] [SCOPUS Times Cited 46]


[4] M. Karimi-Ghartemani, and M. R. Iravani, "A Method for synchronization of power electronic converters in polluted and variable-frequency environments," IEEE Transactions on Power Systems, vol. 19, no. 3, pp. 1263-1270, 2004.
[CrossRef] [Web of Science Times Cited 406] [SCOPUS Times Cited 583]


[5] W. Li, X. Ruan, C. Bao, D. Pan, X. Wang, "Grid synchronization systems of three-phase grid-connected power converters: A complex-vector-filter perspective,"IEEE Transactions on industrial electronics, vol. 61, no. 4, pp. 1855-1870, 2014.
[CrossRef] [Web of Science Times Cited 168] [SCOPUS Times Cited 205]


[6] Y. Han, M. Luo, X. Zhao, J. M. Guerrero, L. Xu, "Comparative performance evaluation of orthogonal-signal-generators-based single-phase PLL algorithms-a survey," IEEE Transactions on Power Electronics, vol. 31, no. 5, pp. 3932-3944, 2016.
[CrossRef] [Web of Science Times Cited 274] [SCOPUS Times Cited 330]


[7] A. Luna, J. Rocabert, J. I. Candela, J. R. Hermoso, R. Teodorescu, F. Blaabjerg P. Rodriguez, "Grid voltage synchronization for distributed generation systems under grid fault conditions," IEEE Transactions on Industry Applications, vol. 51, no. 4, pp. 3414-3425, 2015.
[CrossRef] [Web of Science Times Cited 151] [SCOPUS Times Cited 190]


[8] A. Timbus, M. Liserre, R. Teodorescu, F. Blaabjerg, "Synchronization Methods for Three Phase Distributed Power Generation Systems-an Overview and Evaluation," in Power Electronics Specialists Conference, PESC'05. IEEE 36th, 2005.
[CrossRef] [Web of Science Times Cited 195] [SCOPUS Times Cited 315]


[9] F. Blaabjerg, R. Teodorescu, M. Liserre, A. V. Timbus, "Overview of control and grid synchronization for distributed power generation systems," IEEE Transactions on industrial electronics, vol. 53, no. 5, pp. 1398-1409, 2006.
[CrossRef] [Web of Science Times Cited 3536] [SCOPUS Times Cited 4615]


[10] M. Comanescu, L. Xu, "An improved flux observer based on PLL frequency estimator for sensorless vector control of induction motors," Industrial Electronics, IEEE Transactions on, vol. 53, no. 1, pp. 50-56, 2006.
[CrossRef] [Web of Science Times Cited 116] [SCOPUS Times Cited 169]


[11] V. Kaura, V. Blasko, "Operation of a phase locked loop system under distorted utility conditions," IEEE Transactions on Industry Applications, vol. 33, no. 1, pp. 58-63, 1997.
[CrossRef] [Web of Science Times Cited 755] [SCOPUS Times Cited 1014]


[12] P. Rodriguez, A. Luna, M. Ciobotaru, R. Teodorescu, F. Blaabjerg, "Advanced grid synchronization system for power converters under unbalanced and distorted operating conditions," IEEE Industrial Electronics, IECON 2006-32nd Annual Conference on, 2006.
[CrossRef] [SCOPUS Times Cited 446]


[13] A. V. Timbus, R. Teodorescu, F. Blaabjerg, M. Liserre, P. Rodriguez, "PLL algorithm for power generation systems robust to grid voltage faults," in Proc. of PESC, 2006.
[CrossRef] [SCOPUS Times Cited 78]


[14] L. Liu, H. Li, Z. Wu, Y. Zhou, "A cascaded photovoltaic system integrating segmented energy storages with self-regulating power allocation control and wide range reactive power compensation," IEEE Transactions on Power Electronics, vol. 26, no. 12, pp. 3545-3559, 2011.
[CrossRef] [Web of Science Times Cited 76] [SCOPUS Times Cited 90]


[15] M. Padua, S. Deckmann, G. Sperandio, F. Marafao, D. Colon, "Comparative analysis of synchronization algorithms based on PLL, RDFT and Kalman filter," in Industrial Electronics, 2007. ISIE 2007. IEEE International Symposium on, 2007.
[CrossRef] [Web of Science Times Cited 27] [SCOPUS Times Cited 53]


[16] G. H. Jung, G. C. Cho, S. W. Hong, G. H. Cho, "Dsp based control of high power static VAr compensator using novel vector product phase locked loop," in Power Electronics Specialists Conference, 1996. PESC'96 Record., 27th Annual IEEE, 1996.
[CrossRef]


[17] L. Zheng, H. Geng, G. Yang, "Fast and robust phase estimation algorithm for heavily distorted grid conditions," IEEE Transactions on industrial electronics, vol. 63, no. 11, pp. 6845-6855, 2016.
[CrossRef] [Web of Science Times Cited 71] [SCOPUS Times Cited 77]


[18] S. Golestan, M. Ramezani, J. M. Guerrero, F. D. Freijedo, M. Monfared, "Moving average filter based phase-locked loops: Performance analysis and design guidelines," IEEE Transactions on Power Electronics, vol. 29, no. 6, pp. 2750-2763, 2014.
[CrossRef] [Web of Science Times Cited 423] [SCOPUS Times Cited 504]


[19] S. Chandrasekaran, K. Ragavan, "Adaptive sampling period adjusted sliding DFT for synchronous reference frame PLL," in Power Electronics, Drives and Energy Systems (PEDES), 2014 IEEE International Conference on, 2014.
[CrossRef] [SCOPUS Times Cited 10]


[20] F. Cupertino, E. Lavopa, P. Zanchetta, M. Sumner, L. Salvatore, "Running DFT-based PLL algorithm for frequency, phase, and amplitude tracking in aircraft electrical systems," IEEE Transactions on industrial electronics, vol. 58, no. 3, pp. 1027-1035, 2011.
[CrossRef] [Web of Science Times Cited 85] [SCOPUS Times Cited 101]


[21] N. Guerrero-Rodríguez, A. B. Rey-Boue, E. Bueno, O. Ortiz, E. Reyes-Archundia, "Synchronization algorithms for grid-connected renewable systems: Overview, tests and comparative analysis," Renewable and Sustainable Energy Reviews, 2016.
[CrossRef] [Web of Science Times Cited 20] [SCOPUS Times Cited 28]


[22] Y. F. Wang, Y. W. Li, "Grid synchronization PLL based on cascaded delayed signal cancellation," IEEE Transactions on Power Electronics, vol. 26, no. 7, pp. 1987-1997, 2011.
[CrossRef] [Web of Science Times Cited 244] [SCOPUS Times Cited 293]


[23] S. Golestan, J. M. Guerrero, J. C. Vasquez, "Three-phase PLLs: a review of recent advances," IEEE Transactions on Power Electronics, vol. 32, no. 3, pp. 1894-1907, 2017.
[CrossRef] [Web of Science Times Cited 512] [SCOPUS Times Cited 643]


[24] R. Teodorescu, M. Liserre, P. Rodriguez, "Grid converters for photovoltaic and wind power systems," John Wiley & Sons, 2011.
[CrossRef]


[25] S. Golestan, A. Vidal, A. G. Yepes, J. M. Guerrero, J. C. Vasquez, J. Doval-Gandoy, "A true open-loop synchronization technique," IEEE Transactions on Industrial Informatics, vol. 12, no. 3, pp. 1093-1103, 2016.
[CrossRef] [Web of Science Times Cited 36] [SCOPUS Times Cited 49]


[26] F. Xiao, L. Dong, L. Li, X. Liao, "A novel open-loop frequency estimation method for single-phase grid synchronization under distorted conditions," IEEE Journal of Emerging and Selected Topics in Power Electronics, vol. 5, no. 3, pp. 1287-1297, 2017.
[CrossRef] [Web of Science Times Cited 27] [SCOPUS Times Cited 32]


[27] A. K. Verma, R. K. Jarial, P. Roncero-Sanchez, M. R. Ungarala, J. M. Guerrero, "An improved hybrid pre-filtered open-loop algorithm for three-phase grid synchronization," IEEE Transactions on Industrial Electronics 2020.
[CrossRef] [Web of Science Times Cited 39] [SCOPUS Times Cited 42]


[28] Z. Ali, N. Christofides, L. Hadjidemetriou, E. Kyriakides, Y. Yang, F. Blaabjerg, "Three-phase phase-locked loop synchronization algorithms for grid-connected renewable energy systems: A review," Renewable and Sustainable Energy Reviews, vol. 90, pp. 434-452, 2018.
[CrossRef] [Web of Science Times Cited 103] [SCOPUS Times Cited 148]


[29] S. Golestan, F. D. Freijedo, A. Vidal, J. M. Guerrero, J. Doval-Gandoy, "A quasi-type-1 phase-locked loop structure," IEEE Transactions on Power Electronics, vol. 29, no. 12, pp. 6264-6270, 2014.
[CrossRef] [Web of Science Times Cited 108] [SCOPUS Times Cited 131]


[30] S. Preitl, R.-E. Precup, "An extension of tuning relations after symmetrical optimum method for PI and PID controllers," Automatica, vol. 35, no. 10, pp. 1731-1736, Oct. 1999.
[CrossRef] [Web of Science Times Cited 155] [SCOPUS Times Cited 220]


[31] T. Haidegger, K. Levente, R.-E. Precup, S. Preitl, B. Benyo, Z. Benyo, "Cascade control for telerobotic systems serving space medicine," IFAC Proceedings, vol. 44, no. 1, 2011, pp. 3759-3764.
[CrossRef] [SCOPUS Times Cited 106]




References Weight

Web of Science® Citations for all references: 8,205 TCR
SCOPUS® Citations for all references: 11,283 TCR

Web of Science® Average Citations per reference: 256 ACR
SCOPUS® Average Citations per reference: 353 ACR

TCR = Total Citations for References / ACR = Average Citations per Reference

We introduced in 2010 - for the first time in scientific publishing, the term "References Weight", as a quantitative indication of the quality ... Read more

Citations for references updated on 2024-11-16 05:39 in 211 seconds.




Note1: Web of Science® is a registered trademark of Clarivate Analytics.
Note2: SCOPUS® is a registered trademark of Elsevier B.V.
Disclaimer: All queries to the respective databases were made by using the DOI record of every reference (where available). Due to technical problems beyond our control, the information is not always accurate. Please use the CrossRef link to visit the respective publisher site.

Copyright ©2001-2024
Faculty of Electrical Engineering and Computer Science
Stefan cel Mare University of Suceava, Romania


All rights reserved: Advances in Electrical and Computer Engineering is a registered trademark of the Stefan cel Mare University of Suceava. No part of this publication may be reproduced, stored in a retrieval system, photocopied, recorded or archived, without the written permission from the Editor. When authors submit their papers for publication, they agree that the copyright for their article be transferred to the Faculty of Electrical Engineering and Computer Science, Stefan cel Mare University of Suceava, Romania, if and only if the articles are accepted for publication. The copyright covers the exclusive rights to reproduce and distribute the article, including reprints and translations.

Permission for other use: The copyright owner's consent does not extend to copying for general distribution, for promotion, for creating new works, or for resale. Specific written permission must be obtained from the Editor for such copying. Direct linking to files hosted on this website is strictly prohibited.

Disclaimer: Whilst every effort is made by the publishers and editorial board to see that no inaccurate or misleading data, opinions or statements appear in this journal, they wish to make it clear that all information and opinions formulated in the articles, as well as linguistic accuracy, are the sole responsibility of the author.




Website loading speed and performance optimization powered by: 


DNS Made Easy