Click to open the HelpDesk interface
AECE - Front page banner

Menu:


FACTS & FIGURES

JCR Impact Factor: 0.700
JCR 5-Year IF: 0.700
SCOPUS CiteScore: 1.8
Issues per year: 4
Current issue: Aug 2024
Next issue: Nov 2024
Avg review time: 59 days
Avg accept to publ: 60 days
APC: 300 EUR


PUBLISHER

Stefan cel Mare
University of Suceava
Faculty of Electrical Engineering and
Computer Science
13, Universitatii Street
Suceava - 720229
ROMANIA

Print ISSN: 1582-7445
Online ISSN: 1844-7600
WorldCat: 643243560
doi: 10.4316/AECE


TRAFFIC STATS

1 unique visits
1,157,475 downloads
Since November 1, 2009



Robots online now
bingbot
Amazonbot
Googlebot


SCOPUS CiteScore

SCOPUS CiteScore


SJR SCImago RANK

SCImago Journal & Country Rank




TEXT LINKS

Anycast DNS Hosting
MOST RECENT ISSUES

 Volume 24 (2024)
 
     »   Issue 3 / 2024
 
     »   Issue 2 / 2024
 
     »   Issue 1 / 2024
 
 
 Volume 23 (2023)
 
     »   Issue 4 / 2023
 
     »   Issue 3 / 2023
 
     »   Issue 2 / 2023
 
     »   Issue 1 / 2023
 
 
 Volume 22 (2022)
 
     »   Issue 4 / 2022
 
     »   Issue 3 / 2022
 
     »   Issue 2 / 2022
 
     »   Issue 1 / 2022
 
 
 Volume 21 (2021)
 
     »   Issue 4 / 2021
 
     »   Issue 3 / 2021
 
     »   Issue 2 / 2021
 
     »   Issue 1 / 2021
 
 
  View all issues  








LATEST NEWS

2024-Jun-20
Clarivate Analytics published the InCites Journal Citations Report for 2023. The InCites JCR Impact Factor of Advances in Electrical and Computer Engineering is 0.700 (0.700 without Journal self-cites), and the InCites JCR 5-Year Impact Factor is 0.600.

2023-Jun-28
Clarivate Analytics published the InCites Journal Citations Report for 2022. The InCites JCR Impact Factor of Advances in Electrical and Computer Engineering is 0.800 (0.700 without Journal self-cites), and the InCites JCR 5-Year Impact Factor is 1.000.

2023-Jun-05
SCOPUS published the CiteScore for 2022, computed by using an improved methodology, counting the citations received in 2019-2022 and dividing the sum by the number of papers published in the same time frame. The CiteScore of Advances in Electrical and Computer Engineering for 2022 is 2.0. For "General Computer Science" we rank #134/233 and for "Electrical and Electronic Engineering" we rank #478/738.

2022-Jun-28
Clarivate Analytics published the InCites Journal Citations Report for 2021. The InCites JCR Impact Factor of Advances in Electrical and Computer Engineering is 0.825 (0.722 without Journal self-cites), and the InCites JCR 5-Year Impact Factor is 0.752.

2022-Jun-16
SCOPUS published the CiteScore for 2021, computed by using an improved methodology, counting the citations received in 2018-2021 and dividing the sum by the number of papers published in the same time frame. The CiteScore of Advances in Electrical and Computer Engineering for 2021 is 2.5, the same as for 2020 but better than all our previous results.

Read More »


    
 

  1/2020 - 5

 HIGH-IMPACT PAPER 

A New Approach for Estimating Insulation Condition of Field Transformers Using FRA

MOHD YOUSOF, M. F. See more information about MOHD YOUSOF, M. F. on SCOPUS See more information about MOHD YOUSOF, M. F. on IEEExplore See more information about MOHD YOUSOF, M. F. on Web of Science, AL-AMERI, S. See more information about  AL-AMERI, S. on SCOPUS See more information about  AL-AMERI, S. on SCOPUS See more information about AL-AMERI, S. on Web of Science, AHMAD, H. See more information about   AHMAD, H. on SCOPUS See more information about   AHMAD, H. on SCOPUS See more information about AHMAD, H. on Web of Science, ILLIAS, H. A. See more information about  ILLIAS, H. A. on SCOPUS See more information about  ILLIAS, H. A. on SCOPUS See more information about ILLIAS, H. A. on Web of Science, ARSHAD, S. N. M. See more information about ARSHAD, S. N. M. on SCOPUS See more information about ARSHAD, S. N. M. on SCOPUS See more information about ARSHAD, S. N. M. on Web of Science
 
Extra paper information in View the paper record and citations in Google Scholar View the paper record and similar papers in Microsoft Bing View the paper record and similar papers in Semantic Scholar the AI-powered research tool
Click to see author's profile in See more information about the author on SCOPUS SCOPUS, See more information about the author on IEEE Xplore IEEE Xplore, See more information about the author on Web of Science Web of Science

Download PDF pdficon (640 KB) | Citation | Downloads: 1,051 | Views: 3,519

Author keywords
frequency response, insulation, insulation testing, power transformers

References keywords
response(17), transformer(16), power(16), frequency(16), analysis(13), link(9), insulation(7), transformers(6), yousof(4), sfra(4)
Blue keywords are present in both the references section and the paper title.

About this article
Date of Publication: 2020-02-28
Volume 20, Issue 1, Year 2020, On page(s): 35 - 42
ISSN: 1582-7445, e-ISSN: 1844-7600
Digital Object Identifier: 10.4316/AECE.2020.01005
Web of Science Accession Number: 000518392600005
SCOPUS ID: 85083698122

Abstract
Quick view
Full text preview
Frequency response analysis (FRA) is a tool for evaluating mechanical integrity of transformer's core and winding. However, several studies have reported that FRA is also sensitive to other parameters such as temperature, moisture content and presence of oil. Since some of these parameters are critical in the insulation degradation process, it is interesting to further investigate the possibility of using FRA for insulation assessment. In this paper, the insulation conditions of three field transformers are investigated using FRA. This is performed after statistical analysis on the response suggested no mechanical damage on the transformers. The responses are further analyzed to determine the percentage of change of winding capacitance. This is achieved by comparing resonance frequencies between the responses. The percentage of change represents the amount of degradation in the insulation. This is because as the insulation condition degrades, the response is shifted towards lower frequencies. This new investigation demonstrates the applicability of FRA to estimate the insulation degradation.


References | Cited By  «-- Click to see who has cited this paper

[1] M. F. M. Yousof, C. Ekanayake, and T. K. Saha, "Examining the ageing of transformer insulation using FRA and FDS techniques," IEEE Trans. Dielectr. Electr. Insul., vol. 22, no. 2, pp. 1258-1265, Apr. 2015.
[CrossRef] [Web of Science Times Cited 28] [SCOPUS Times Cited 40]


[2] S. M. Gubanski et al., "Dielectric response methods for diagnostics of power transformers," Electr. Insul. Mag. IEEE, vol. 19, no. 3, pp. 12-18, May/June 2003.
[CrossRef] [Web of Science Times Cited 163] [SCOPUS Times Cited 241]


[3] A. A. Reykherdt and V. Davydov, "Case studies of factors influencing frequency response analysis measurements and power transformer diagnostics," Electr. Insul. Mag. IEEE, vol. 27, no. 1, pp. 22-30, Jan./Feb. 2011.
[CrossRef] [Web of Science Times Cited 50] [SCOPUS Times Cited 59]


[4] K. G. N. B. Abeywickrama, Y. V. Serdyuk, and S. M. Gubanski, "Exploring Possibilities for Characterization of Power Transformer Insulation by Frequency Response Analysis (FRA)," IEEE Trans. Power Del., vol. 21, no. 3, pp. 1375-1382, July 2006.
[CrossRef] [Web of Science Times Cited 98] [SCOPUS Times Cited 122]


[5] M. Bagheri, B. T. Phung, T. Blackburn, and A. Naderian, "Influence of temperature on frequency response analysis of transformer winding," in IEEE Electr. Insul. Conf. (EIC), 2013, pp. 40-44.
[CrossRef] [SCOPUS Times Cited 17]


[6] C. Krause, W. Goetz, and B. Heinrich, "The impact of drying and oil impregnation conditions and of temperature cycles on the clamping force of power transformer windings," in Conf. Rec. IEEE Int. Symp. Electr. Insul. , 2002, pp. 350-353.
[CrossRef] [Web of Science Times Cited 16] [SCOPUS Times Cited 21]


[7] P. Picher et al. "Mechanical-Condition Assessment of Transformer Windings Using Frequency Response Analysis (FRA)," CIGRE working group A 2, 2008. [Online] Available: Temporary on-line reference link removed - see the PDF document

[8] N. Abeywickrama, C. Ekanayake, Y. V Serdyuk, and S. M. Gubanski, "Effects of the Insulation Quality on the Frequency Response of Power Transformers," J. Electr. Eng., vol. 1, no. 4, pp. 534-542, 2006.
[CrossRef]


[9] M. Hartje, "A new way of FRA (frequency response analysis)," presented at the 19th Int. Symp. High Volt. Eng., Pilsen, Czech Republic, 2015.

[10] N. Hashemnia, S. Islam, and M. A. S. Masoum, "Understanding Power Transformer Frequency Response Analysis Signatures," IEEE Electr. Insul. Mag., vol. 29, no. 3, pp. 48-56, May/June 2013.
[CrossRef] [Web of Science Times Cited 124] [SCOPUS Times Cited 170]


[11] F. Predl, "Interpretation of Sweep Frequency Response Analysis (SFRA) Measurement Results," presented at the Techcon Asia-Pacific,Sydney, NSW, 2016. [Online] Available: Temporary on-line reference link removed - see the PDF document

[12] O. Sarneroth. (2001, Jan. 1). Insulation Materials [Online]. Available: library.e.abb.com

[13] W. Ziomek, "Transformer Electrical Insulation [Editorial]," IEEE Trans. Dielectr. Electr. Insul., vol. 19, no. 6, pp. 1841-1842, Dec. 2012.
[CrossRef] [Web of Science Times Cited 24] [SCOPUS Times Cited 33]


[14] T. A. Prevost, "Degradation of Cellulose Insulation in Liquid-Filled Power Transformers," presented at the 4th Annual Technical Conference New Diagnostic Concepts for Better Asset Management, 2005. [Online] Available: Temporary on-line reference link removed - see the PDF document

[15] P. Gill, Electrical power equipment maintenance and testing, 2nd ed., Florida, CRCPress, 2008. [Online] Available: Temporary on-line reference link removed - see the PDF document

[16] A. Marinescu, and C. L. Ungureanu, "About Axial Clamping Force Monitoring at Power Transformer Windings during their Active Lifetime," Ann. Univ. Craiova, Electr. Eng. Series, no. 32, pp. 56-61, 2008. [Online] Available: Temporary on-line reference link removed - see the PDF document

[17] T. Sano and K. Miyagi, "Influence factors on FRA waveforms", in IEEE International Conference on Condition Monitoring and Diagnosis (CMD), 2012, pp. 601-604.
[CrossRef] [SCOPUS Times Cited 3]


[18] M. F. M. Yousof, "Frequency Response Analysis for Transformer Winding Condition Monitoring," Ph.D. dissertation, Sch. Inf. Technol. Electr. Eng., The Univ. of Queensland, Brisbane, Australia, 2015. [Online] Available: Temporary on-line reference link removed - see the PDF document

[19] IEEE Guide for the Application and Interpretation of Frequency Response Analysis for Oil-Immersed Transformers, IEEE Standard C57.149, 2012. [Online] Available: Temporary on-line reference link removed - see the PDF document

[20] Power transformers - Part 18: Measurement of frequency response, IEC 60076-18, 2012. [Online] Available: Temporary on-line reference link removed - see the PDF document

[21] M. F. M. Yousof, C. Ekanayake, and T. K. Saha, "Study of transformer winding deformation by frequency response analysis," in IEEE Power Energy Soc. Gen. Meet. (PESGM), 2013, pp. 1-5.
[CrossRef] [SCOPUS Times Cited 6]


[22] M. F. M. Yousof, S. Riang, and M. K. A. Uyup, "The influence of data size in statistical analysis of power transformer frequency response," in 2016 IEEE Int. Conf. Power Energy (PECon), 2016, pp. 595-599.
[CrossRef] [SCOPUS Times Cited 4]


[23] K. P. Badgujar, M. Maoyafikuddin, and S. V. Kulkarni, "Alternative statistical techniques for aiding SFRA diagnostics in transformers," IET Gener. Transm. Distrib., vol. 6, no. 3, p. 189, March 2012.
[CrossRef] [Web of Science Times Cited 73]


[24] G. M. Kennedy, A. J. McGrail, and J. A. Lapworth, "Using cross-correlation coefficients to analyze transformer sweep frequency response analysis (SFRA) traces," in IEEE PES Conf. Expo. (PowerAfrica), 2007, pp. 16-20.
[CrossRef] [SCOPUS Times Cited 44]


[25] G. Kennedy, A. McGrail, and J. Lapworth, "Transformer sweep frequency response analysis (SFRA)," Energize, pp. 28-33, Oct. 2007. [Online] Available: Temporary on-line reference link removed - see the PDF document

[26] A. Akbaril, H. Firoozil, H. Borsi, and M. Kharezi, "Assessment of Drying Quality for Power Transformer during Manufacturing Process Using Variation of Transfer Function," in IEEE Conf. on Electr. Insul. and Dielectr. Phenom. (CEIDP), 2006, pp. 113-116.
[CrossRef] [Web of Science Times Cited 4] [SCOPUS Times Cited 6]


[27] C. Ekanayake, S. M. Gubanski, A. Graczkowski, and K. Walczak, "Frequency response of oil impregnated pressboard and paper samples for estimating moisture in transformer insulation," IEEE Trans. Power Del., vol. 21, no. 3, pp. 1309-1317, July 2006.
[CrossRef] [Web of Science Times Cited 200] [SCOPUS Times Cited 288]




References Weight

Web of Science® Citations for all references: 780 TCR
SCOPUS® Citations for all references: 1,054 TCR

Web of Science® Average Citations per reference: 28 ACR
SCOPUS® Average Citations per reference: 38 ACR

TCR = Total Citations for References / ACR = Average Citations per Reference

We introduced in 2010 - for the first time in scientific publishing, the term "References Weight", as a quantitative indication of the quality ... Read more

Citations for references updated on 2024-11-16 20:01 in 115 seconds.




Note1: Web of Science® is a registered trademark of Clarivate Analytics.
Note2: SCOPUS® is a registered trademark of Elsevier B.V.
Disclaimer: All queries to the respective databases were made by using the DOI record of every reference (where available). Due to technical problems beyond our control, the information is not always accurate. Please use the CrossRef link to visit the respective publisher site.

Copyright ©2001-2024
Faculty of Electrical Engineering and Computer Science
Stefan cel Mare University of Suceava, Romania


All rights reserved: Advances in Electrical and Computer Engineering is a registered trademark of the Stefan cel Mare University of Suceava. No part of this publication may be reproduced, stored in a retrieval system, photocopied, recorded or archived, without the written permission from the Editor. When authors submit their papers for publication, they agree that the copyright for their article be transferred to the Faculty of Electrical Engineering and Computer Science, Stefan cel Mare University of Suceava, Romania, if and only if the articles are accepted for publication. The copyright covers the exclusive rights to reproduce and distribute the article, including reprints and translations.

Permission for other use: The copyright owner's consent does not extend to copying for general distribution, for promotion, for creating new works, or for resale. Specific written permission must be obtained from the Editor for such copying. Direct linking to files hosted on this website is strictly prohibited.

Disclaimer: Whilst every effort is made by the publishers and editorial board to see that no inaccurate or misleading data, opinions or statements appear in this journal, they wish to make it clear that all information and opinions formulated in the articles, as well as linguistic accuracy, are the sole responsibility of the author.




Website loading speed and performance optimization powered by: 


DNS Made Easy