160 results found.
Year: 2022, Volume: 22, Number: 1
... modeling of wind turbine used in partial scale power converter based wind turbines. systems is required to examine dynamic events. While stator terminals are connected to the grid transformer, Wind turbines consist of three main parts called a rotor, its rotor terminals are connected to the back-to-back tower, and nacelle. There are a hub ...
Terms matched: 1 - Score: 6 - 1,838k
Year: 2021, Volume: 21, Number: 4
... J. K. Mills, and D. Sun, "Two-stage charging strategy for Table III shows that coordinate charging and the plug-in electric vehicles at the residential transformer level," IEEE provision of regulation service (discharging) give the lowest Transactions on Smart Grid, vol. 4, no. 3, pp. ...
Terms matched: 1 - Score: 3 - 1,645k
Year: 2021, Volume: 21, Number: 3
... 21, Number 3, 2021 A Power Electronic Traction Transformer Model for a New Medium Voltage DC Electric Railway ... Traction model and simulations of a whole MVDC catenary-line fed transformers (PETT) were developed for the existent Medium ... module," 2017 IEEE Energy Convers. Congr. transformer-based railway traction systems: challenges and Expo. ( ...
Terms matched: 3 - Score: 31 - 2,068k
Year: 2021, Volume: 21, Number: 3
... simulation results for proposed+ strategy, section VI presents the experimental verifications G 3-˜ Lfy Vdc Inverter- Lfb and section VII concludes the paper. 3-˜ Gnd Inverter Transformer PV String Vpv PWM Pulses II. BASIC METHODOLOGY OF APC ig Ipv Inverter/ vg In this section, the basic theory of APC was discussed EAPC control ...
Terms matched: 1 - Score: 6 - 2,507k
Year: 2021, Volume: 21, Number: 2
... lose the signals at a sampling rate of 10 kHz. required information. The sampling frequency of data Potential generation was 10kHz resulting in 2000 points in a 200ms Transformer period. The fundamental frequency of each signal was ZMPT 101b PC 50Hz. The simulated signals are shown in Fig. 3. Potential 3 € Phase AC ...
Terms matched: 1 - Score: 6 - 1,483k
Year: 2021, Volume: 21, Number: 2
... controlled to achieve power balance. The research AC bus. AC bus is integrated with the grid through a 100 contributions of this article are as follows. kVA transformer (415V/3.3kV). AC and DC subgrids are ‚ KF based novel power smoothing technique is coupled by a bidirectional ILC and a filter [23 ...
Terms matched: 1 - Score: 3 - 1,551k
Year: 2020, Volume: 20, Number: 4
... . From (1 ), the stator currents can wound-rotor induction generator, RSC, an intermediary DC- be expressed as link circuit, GSC, a coupling transformer, and an associated ds € Lmidr ƒ control system. As described, the stator is directly connected ids € ƒ to the grid via a three-phase ...
Terms matched: 1 - Score: 6 - 1,690k
Year: 2020, Volume: 20, Number: 4
... associated to the existence of communication equipment that and charging of plug-in electric vehicles to assess, use the earthing conductor for signal grounding purposes respectively, voltage unbalance and transformer aging. [6 ], which may suffer from disruption of communication Digital Object Identifier 10.4316/AECE.2020.04006 45 1582-7445© 2020 AECE Advances in Electrical and Computer ...
Terms matched: 1 - Score: 22 - 1,302k
Year: 2020, Volume: 20, Number: 4
... is organized as follows. Section I describes the superconducting transformer type [3-5], solid state type [ ... was investigated in [19]. To evaluate the transformers are connected in series to the main grid and ... to Fig. 16(c) ASCC is of transformer-type superconducting fault current limiter due to adjusted to keep ...
Terms matched: 3 - Score: 47 - 1,381k
Year: 2020, Volume: 20, Number: 3
... and a Zmod DAC 1411 (modules also manufactured on the mid winding of the transformer (vsec) are described in by Digilent) implementing the analog to digital ... implementations of the input current ƒ 0 € ƒ sensors use circuits based on current transformers that also ƒ R € R C ƒ alter the input valley current waveform ...
Terms matched: 2 - Score: 34 - 1,807k