163 results found.
Year: 2019, Volume: 19, Number: 1
... grid-side were verified. Those oscillations and grid-connected full-controlled five-leg single-phase to may cause malfunction of equipment connected to the Point three-phase converter supplying an induction motor is of Common Coupling (PCC). On top of that, tracking illustrated with more details. The system parameters are the execution quality was dependent on the irradiance variation following ...
Terms matched: 1 - Score: 3 - 1,518k
Year: 2019, Volume: 19, Number: 1
... , G. Brezeanu, "Investigation of electrothermal behaviour of a linear voltage regulator and its maximum and minimum values of the dissipated power: protection circuits by simulator coupling," Semiconductor Conference N=2.12 compared to N=3.36 for the current limit protection (CAS), 2013 International, vol.2, no., ...
Terms matched: 1 - Score: 3 - 1,362k
Year: 2018, Volume: 18, Number: 1
... . Liwang, F. Haichao, Z. Yifeng, H. Yihua, "Analysis on scheme, IEE Proceedings- Control Theory and Applications, vol. coupling effect of 2-DOF direct drive induction motor based on 3-D 149, no. 4, pp. 285-290, 2002. doi:10.1049/ip-cta:20020438 ...
Terms matched: 1 - Score: 3 - 1,688k
Year: 2018, Volume: 18, Number: 4
... Rectification of Single Error, Identification of Double Error(M-RSE-IDE) various noise origins such as environmental variation [5 ], extended-Hamming code, and Quintuplication error correction coupling of Crosstalk [6 ,7 ], transit voltage fluctuations [8 ], scheme serves as the backbone for the proposed technique. process variations [9 ...
Terms matched: 1 - Score: 43 - 1,563k
Year: 2018, Volume: 18, Number: 4
... This section presents the experimental results with the simulated through the insertion of a plastic clamp with four scale model laboratory. The experiments have been side-by-side screw-nuts on the coupling between the speed accomplished considering three types of fluids being reducer and the PMSM. This causes the presence of a pumped in the scale model laboratory. The ...
Terms matched: 1 - Score: 6 - 1,921k
Year: 2018, Volume: 18, Number: 4
... ,8 7 B4H411 1,04 B4H_4-01 428,33 3 YB06-G1 22 1,114 0,955 B06_2-01 190 -20,8 TABLE V. LIST OF COUPLING TRANSFORMERS TOGETHER WITH THEIR 4 YB07-G1 15.8 1,114 0,955 DO7_2-01 112,8 -21,9 PARAMETERS Node. Node. Turns ratio 5 YB14-G1 ...
Terms matched: 1 - Score: 8 - 1,168k
Year: 2018, Volume: 18, Number: 3
... , Vqs1, Vds2, Vqs2 influence the current system* ids1, iqs1, ids2, iqs2, the flux r € dr and the torque Te For decoupling the axes d and q, we define a new set of four command variables: Vds1a, Vqs1a, Vds2a, Vqs2a: Vds1, 2 € Vds1 ...
Terms matched: 1 - Score: 10 - 1,602k
Year: 2018, Volume: 18, Number: 3
... the electromagnetic torque on the rotor angle of model SRM, assuming no mutual magnetic coupling rotation, with phase current as the parameter [0, 4, 14 ... phases. Because of the perpendicular position of the adjacent phase windings, mutual magnetic couplings in the tested SRM design occur only due to rotor asymmetry and the uneven ...
Terms matched: 2 - Score: 8 - 1,379k
Year: 2018, Volume: 18, Number: 3
... in structure than on-chip wires, adopted to develop a simple noise model with a single parameter and use the superposition theorem to extend the therefore the mitigation for large coupling noise is difficult. number of TSV lines that produce the noise. The proposed As such, a designer should analyze and predict the TSV-to- regression model ...
Terms matched: 1 - Score: 72 - 1,556k
Year: 2018, Volume: 18, Number: 2
... communication, reducing thus the protocol complexity to deliver messages between systems. Figure 2. ENoC overview with wired routers and wireless hub The addition of new elements (coupling connection) is performed by ENoC through the wireless link (hub), as follows: ‚ The wireless hub is always listening to new connections; Figure ...
Terms matched: 1 - Score: 13 - 1,316k