160 results found.
Year: 2016, Volume: 16, Number: 1
... =G and G21= -G), or by By introducing an ideal transformer into a unidirectional choosing certain values for the two conductance groups circuit diagram, ... Nonreciprocal Lossless Two-Port Networks [6] F. Yuan, "CMOS Gyrator-C Active Transformers," 2007 IEEE Using Gyrators and Inverters," IEEE Trans. Microwave ...
Terms matched: 2 - Score: 8 - 849k
Year: 2012, Volume: 12, Number: 1
... operated in STATCOM and then trained NFC is used in experimental parallel, the input transformer becomes bulky [21]. study. This paper is organized as follows ... surge arresters, active power filters, robust structure and independent from mathematical model isolation transformers, uninterruptible power supplies and of controlled system. Recently, intelligent controllers as ...
Terms matched: 2 - Score: 6 - 994k
Year: 2010, Volume: 10, Issue: 4
... For this reason, the angle between the with the help of a 12 volt transformer and sensors connected current and the voltage changes between 0 ï‚° and 90 ï‚° ... inductive loads such detector have been applied at the inputs of the as generators, transformers, coils and motors is tried to be microcontroller and the data crossing at ...
Terms matched: 2 - Score: 5 - 4,124k
Year: 2011, Volume: 11, Number: 4
... value δ max depends on the system load flow mathematical model, the following generator transformer impedance and the network relationships may be written; configuration and normally is found ... consists of 62 buses, condition for the study system when the reactive power 31 transformers, 64 transmission lines, 19 synchronous limits of the system generators are represented ...
Terms matched: 2 - Score: 5 - 483k
Year: 2014, Volume: 14, Number: 1
... N1, 0) ï‚®  =  ,  blocks: address transformer (AT) and address generator  y  2 ï€ i ï€ j ... (20) direct hardware synthesis of AGUs can be performed. address. Address transformers modify only offset part of the For more details see, for example [ ...
Terms matched: 2 - Score: 5 - 735k
Year: 2013, Volume: 13, Number: 2
... transmission branch Locational Marginal Price (LMP) differences (inconsistency of (line or transformer) usually constrained by thermal LMPs) that arise at the boundary buses between ... If we look at the Table III, the LMP difference between the From-bus and Transformers 9 Branch Charging (inj) 1345.93 To-bus ends equals the absolute value of ...
Terms matched: 2 - Score: 5 - 717k
Year: 2024, Volume: 24, Number: 1
... fake news: International Journal of Communication Networks and Distributed Robust generalisable news classification using transformers," in 2021 Systems, vol. 28, no. 2, ... with percentages of 96.18% and 96.20% Real Fake respectively. Compared to state-of-the-art transformer-based Train set 3,360 3,060 Val set 1,120 1 ...
Terms matched: 2 - Score: 5 - 1,515k
Year: 2018, Volume: 18, Number: 3
... Diagnosis of Winding Faults in a aliased components at different reporting rates and the high Transformer using Transient and Tteady state Currents," accuracy that must be fulfilled in ... a) Frequency, (b) Magnitude test (NL) composed by an autotransformer, a rectifier bridge, a for voltage, (c) Magnitude test ...
Terms matched: 2 - Score: 5 - 1,649k
Year: 2007, Volume: 7, Issue: 2
... in Electrical and Computer Engineering Volume 7 (14), Number 2 (28), 2007 Controlled Interphase Power Controller (IPC) on the Base of Squashed Transformer Mihail KIORSAK, Leo KALININ, Tudor AMBROS Technical University, 31 August str. 78, MD-2012 Kishinau Institute of Power Engineering, Academy 5 str., ...
Terms matched: 1 - Score: 315 - 1,117k
Year: 2011, Volume: 11, Number: 2
... generating higher or lower where the low frequency PWM pulse is modulating a higher resonant frequency required by the ZVS inverter's intensity radiations, as demanded. The CW commercial transformer. The method presented allows a continuous magnetron (and its conventional power supply) is not control of both power and energy (duty-cycle) at the inverter's ...
Terms matched: 1 - Score: 45 - 759k