270 results found containing all search terms.
Year: 2015, Volume: 15, Number: 1
... calculation. wire sag which has virtually no influence on the result of the elements Data output calculation due to the fact that the wire sag (up to ten ... power in instantaneous magnetizing currents, the power transformers the electric power grid increases and transmission capacity are designed on the basis of the T-shaped equivalent circuit of the power ...
Terms matched: 2 - Score: 36 - 785k
Year: 2015, Volume: 15, Number: 1
... also provide a include self-healing, safety, compatibility, high efficiency, new important data source and development direction for interaction, high quality, etc. Smart grid ... variable, and the occurrence time of fault is determined by protection scheme for series-compensated transmission lines," IEEE the second dimensional variable. All of these results can ...
Terms matched: 2 - Score: 34 - 583k
Year: 2014, Volume: 14, Number: 2
... ] that are modulated cold temperature) shortens the lifetime of satellite by the navigation data D  t  and the ranging code C  t . electronics ... the navigation signal, but investigate approximately+/- 35 kHz Consequently, multipath transmission reduces the precision range and, if not successful, switch to the next ...
Terms matched: 2 - Score: 10 - 700k
Year: 2014, Volume: 14, Number: 4
... power line channel is not an ideal signal transmission In order to further improve the data throughput of PLC carrier due to the presence of impulse noise. The obvious ... used for information SD method is a special kind of ML method, first proposed transmission over the lines installed for delivering the by Viterbo [13]. It ...
Terms matched: 2 - Score: 21 - 862k
Year: 2014, Volume: 14, Number: 4
... and L. Trifina, "Component Recursive Systematic high data tare wireless commnunication: Performance criterion and Convolutional Code ... cooperative diversity or cooperative communication [2]. direct transmission for low impulse rate and slightly worse This implies ... sd, Rc ,rd the coding rates corresponding to transmissions on the three channels and sample with zero mean ...
Terms matched: 3 - Score: 17 - 785k
Year: 2014, Volume: 14, Number: 4
... 16-QAM modulation better protects the bit ai than the bit bi. size of a data block at the turbo encoder input is of 2ï‚´752 7 bits. We considered ... the frame error rate from a value FERnc, in the case of an uncoded transmission, to a value FERTC, in the case of a turbo coded transmission ...
Terms matched: 2 - Score: 16 - 684k
Year: 2014, Volume: 14, Number: 4
... ,1.0 3) Evaluate f( x) for each vector in the HM database as Capacity factor of biomass, wind and SPV DG 0.85, 0.3, ... search algorithm inclusing voltage rise and wind DG combination. issue," Generation, Transmission& Distribution, IET, vol. 7, no. 9, Fig ...
Terms matched: 2 - Score: 10 - 818k
Year: 2014, Volume: 14, Number: 4
... . P v (4) dynamical behavior and that simultaneously communicate through the PCB data bus with other ICs on the board. The Then, (3) ... and distributed procedure is illustrated in Fig. 1b and allows for the interconnects (transmission lines). simulation of an arbitrary electrical network. The First of all ...
Terms matched: 2 - Score: 22 - 1,084k
Year: 2014, Volume: 14, Number: 3
... It does dependent on the temperature coefficient of photodiode. not matter whether the sensor data processing is in analog or Besides some attempts of the correction for photodiodes digital ... sensors interchangeability in spite of measurement of the UVR irradiance). This requires a transmission to the individual conversion functions. corresponding switching the measuring scheme between the working ...
Terms matched: 2 - Score: 26 - 704k
Year: 2014, Volume: 14, Number: 3
... acquired from a digital the sliding contact between two components. Pantograph line-scan camera. Data are simultaneously processed according arcing faults occur because of following reasons [5 ] ... the most utilized component inspection cannot be performed over the entire line. for the transmission of electric power from the overhead Additionally, the locomotives must be maintained in ...
Terms matched: 2 - Score: 21 - 1,144k