Click to open the HelpDesk interface
AECE - Front page banner

Menu:


FACTS & FIGURES

JCR Impact Factor: 0.825
JCR 5-Year IF: 0.752
SCOPUS CiteScore: 2.5
Issues per year: 4
Current issue: May 2022
Next issue: Aug 2022
Avg review time: 78 days
Avg accept to publ: 48 days
APC: 300 EUR


PUBLISHER

Stefan cel Mare
University of Suceava
Faculty of Electrical Engineering and
Computer Science
13, Universitatii Street
Suceava - 720229
ROMANIA

Print ISSN: 1582-7445
Online ISSN: 1844-7600
WorldCat: 643243560
doi: 10.4316/AECE


TRAFFIC STATS

1,921,792 unique visits
743,568 downloads
Since November 1, 2009



Robots online now
Googlebot
bingbot


SCOPUS CiteScore

SCOPUS CiteScore


SJR SCImago RANK

SCImago Journal & Country Rank




TEXT LINKS

Anycast DNS Hosting






LATEST NEWS

2022-Jun-28
Clarivate Analytics published the InCites Journal Citations Report for 2021. The InCites JCR Impact Factor of Advances in Electrical and Computer Engineering is 0.825 (0.722 without Journal self-cites), and the InCites JCR 5-Year Impact Factor is 0.752.

2022-Jun-16
SCOPUS published the CiteScore for 2021, computed by using an improved methodology, counting the citations received in 2018-2021 and dividing the sum by the number of papers published in the same time frame. The CiteScore of Advances in Electrical and Computer Engineering in 2021 is 2.5, the same as for 2020 but better than all our previous results.

2021-Jun-30
Clarivate Analytics published the InCites Journal Citations Report for 2020. The InCites JCR Impact Factor of Advances in Electrical and Computer Engineering is 1.221 (1.053 without Journal self-cites), and the InCites JCR 5-Year Impact Factor is 0.961.

2021-Jun-06
SCOPUS published the CiteScore for 2020, computed by using an improved methodology, counting the citations received in 2017-2020 and dividing the sum by the number of papers published in the same time frame. The CiteScore of Advances in Electrical and Computer Engineering in 2020 is 2.5, better than all our previous results.

2021-Apr-15
Release of the v3 version of AECE Journal website. We moved to a new server and implemented the latest cryptographic protocols to assure better compatibility with the most recent browsers. Our website accepts now only TLS 1.2 and TLS 1.3 secure connections.

Read More »


SEARCH THE JOURNAL CONTENT


Enter one or more keywords to search for.
For exact phrase matching use quotation marks (e.g. "speed controller").
Note that '*' and '?' wildcards are supported.

Search for:

Results per page:

Match: any search words all search words

Search results for: coupling

149 results found.

15 pages of results.
Sorted by relevance / Sort by date
Year: 2013, Volume: 13, Number: 3
... stability, transient stability. second level copes with the synchronization or the islanding algorithms [6-8]; this control works in the point of common I. INTRODUCTION coupling. Finally the tertiary control deals with the energy Intelligent Microgrids integrate different energy management, the electrical market and the energy exchange resources, especially renewable sources, ...
Terms matched: 1  -  Score: 3  -  704k
Year: 2013, Volume: 13, Number: 3
... . Lange, K. Hameyer, "System Simulation of a PMSM Permanent-Magnet Synchronous Motors", IEEE Trans. Magn., vol. Servo Drive Using Field-Circuit Coupling", IEEE Trans. Magn., vol. 46, no. 5, pp. 1228- 1234, 2010. [Online]. Available ...
Terms matched: 1  -  Score: 3  -  885k
Year: 2013, Volume: 13, Number: 2
... [5] B. Tersteegen, C. Schröders, S. Stein, H. J. Haubrich, "Algorithmic sp Challenges and Current Problems in Market Coupling Regimes", where PLj is specified (constant) active power load in j- European Trans. Electrical Power, vol. 19, no. 4 ...
Terms matched: 1  -  Score: 3  -  717k
Year: 2013, Volume: 13, Number: 2
... is the winding current, A is the cross area of lateral tooth, δ is the length of air gap, μ0 is the permeability of air. The coupling extents among the three phases of magnetic circuit are negligible because of 3-phase windings displaying a symmetrical distribution with 120 degree in space. Hence, to simplify the ...
Terms matched: 1  -  Score: 3  -  1,514k
Year: 2011, Volume: 11, Number: 1
... 2 2 effect which can be computed assuming the current I f p € fs 2 flowing through the red wire and I/2 currents flowing -computation of the coupling coefficient k € 2, fp through the blue wires. Computing the magnetic energy Wm it follows that the parasitic inductance is Lp= 2 Wm/I2 ...
Terms matched: 1  -  Score: 3  -  940k
Year: 2015, Volume: 15, Number: 3
... the consumer. In most cases, the consumer of electricity is responsible for altering the power quality in the II. STRATEGIES FOR COMMAND AND CONTROL point of common coupling (PCC). Regarding power quality issues, harmonics have a significant importance, because The aim of active filters control is to generate signals for many of ...
Terms matched: 1  -  Score: 3  -  1,263k
Year: 2015, Volume: 15, Number: 3
... negative correlation with considered worthy if it is confirmed by all indices. In Table RAND is expected. Such behaviour for the majority of III we present all possible couplings of distance metrics used datasets was found for HEOM. Other distances only for to calculate internal measures. The best results (triple some datasets were highly negatively ...
Terms matched: 1  -  Score: 3  -  1,251k
Year: 2011, Volume: 11, Number: 1
... s (k) (10) and sensor i, the matrix P is an m n sized matrix, a collection of impulse responses, describing the acoustic coupling of the enclosure. where Y s (k)= y1 s s (k ), y2 s (k ), .. yn (k) ...
Terms matched: 1  -  Score: 3  -  807k
Year: 2013, Volume: 13, Number: 1
... 20 exactly, in the future work. In addition, the difference may 15 be due to the elasticity of the disc brake, the misalignment 10 of the coupling and the motor prototype. 5 It is also seen from Fig. 11 that the maximum value of the 0 0 10 20 30 40 50 60 70 ...
Terms matched: 1  -  Score: 3  -  649k
Year: 2010, Volume: 10, Issue: 4
... Es s s r € u s € Rs i s € Ls. s (5) avoided. Secondly, the rotor flux orientation avoids cross- dt coupling blocks in the d and q current regulators. The only Estimated back-emf, and as well all the variable used in (5 ), disadvantage is the ...
Terms matched: 1  -  Score: 3  -  2,453k
Result Pages: << Previous 3 4 5 6 7 8 9 10 11 12 13 14 15 Next >>


Search took 0.259 seconds


The search engine database includes all papers published after 2007, including titles, author names, abstracts, keywords, full papers text, references and citations. For papers published between 2001 and 2006, please visit the Archive section.


We invite you to try the most frequently used search terms:

system - power - control - fault - network - load - model - frequency - converter - transformer - harmonic - computer - algorithm - cancer - simulation - computer - estimate - optimal control - expert system - electromagnetic - interference - data transmission - neural network - electrocardiogram signal - model - cluster - design - wavelet - antenna - wireless sensor - coupling - robust - noise - signal processing - system identification - translation - nonlinear systems - induction motor - speed controller - shape optimization - fuzzy network - wireless sensor network


Website loading speed and performance optimization powered by: