Click to open the HelpDesk interface
AECE - Front page banner

Menu:


FACTS & FIGURES

JCR Impact Factor: 0.800
JCR 5-Year IF: 1.000
SCOPUS CiteScore: 2.0
Issues per year: 4
Current issue: Feb 2024
Next issue: May 2024
Avg review time: 77 days
Avg accept to publ: 48 days
APC: 300 EUR


PUBLISHER

Stefan cel Mare
University of Suceava
Faculty of Electrical Engineering and
Computer Science
13, Universitatii Street
Suceava - 720229
ROMANIA

Print ISSN: 1582-7445
Online ISSN: 1844-7600
WorldCat: 643243560
doi: 10.4316/AECE


TRAFFIC STATS

2,546,577 unique visits
1,011,895 downloads
Since November 1, 2009



Robots online now
Googlebot


SCOPUS CiteScore

SCOPUS CiteScore


SJR SCImago RANK

SCImago Journal & Country Rank




TEXT LINKS

Anycast DNS Hosting
FEATURED ARTICLES

Application of the Voltage Control Technique and MPPT of Stand-alone PV System with Storage, HIVZIEFENDIC, J., VUIC, L., LALE, S., SARIC, M.
Issue 1/2022

AbstractPlus






LATEST NEWS

2023-Jun-28
Clarivate Analytics published the InCites Journal Citations Report for 2022. The InCites JCR Impact Factor of Advances in Electrical and Computer Engineering is 0.800 (0.700 without Journal self-cites), and the InCites JCR 5-Year Impact Factor is 1.000.

2023-Jun-05
SCOPUS published the CiteScore for 2022, computed by using an improved methodology, counting the citations received in 2019-2022 and dividing the sum by the number of papers published in the same time frame. The CiteScore of Advances in Electrical and Computer Engineering for 2022 is 2.0. For "General Computer Science" we rank #134/233 and for "Electrical and Electronic Engineering" we rank #478/738.

2022-Jun-28
Clarivate Analytics published the InCites Journal Citations Report for 2021. The InCites JCR Impact Factor of Advances in Electrical and Computer Engineering is 0.825 (0.722 without Journal self-cites), and the InCites JCR 5-Year Impact Factor is 0.752.

2022-Jun-16
SCOPUS published the CiteScore for 2021, computed by using an improved methodology, counting the citations received in 2018-2021 and dividing the sum by the number of papers published in the same time frame. The CiteScore of Advances in Electrical and Computer Engineering for 2021 is 2.5, the same as for 2020 but better than all our previous results.

2021-Jun-30
Clarivate Analytics published the InCites Journal Citations Report for 2020. The InCites JCR Impact Factor of Advances in Electrical and Computer Engineering is 1.221 (1.053 without Journal self-cites), and the InCites JCR 5-Year Impact Factor is 0.961.

Read More »


SEARCH THE JOURNAL CONTENT


Enter one or more keywords to search for.
For exact phrase matching use quotation marks (e.g. "speed controller").
Note that '*' and '?' wildcards are supported.

Search for:

Results per page:

Match: any search words all search words

Search results for: transformer

158 results found.

16 pages of results.
Sort by relevance / Sorted by date ▼
Year: 2012, Volume: 12, Number: 1
... operated in STATCOM and then trained NFC is used in experimental parallel, the input transformer becomes bulky [21]. study. This paper is organized as follows ... surge arresters, active power filters, robust structure and independent from mathematical model isolation transformers, uninterruptible power supplies and of controlled system. Recently, intelligent controllers as ...
Terms matched: 2  -  Score: 6  -  994k
Year: 2011, Volume: 11, Number: 4
... 40] G. Steiner, H. Zangl, P. Fulmek, and G. Brasseur, "A tuning 2009. DOI: 10.1109/AIM.2009.5229736. transformer for the automatic adjustment of resonant loop antennas in [18] L. W. Mayer, Antena design for future multi-standard and multi- RFID systems, ...
Terms matched: 1  -  Score: 3  -  1,343k
Year: 2011, Volume: 11, Number: 3
... model has been proposed for solving the data exchange The power system line data includes transformer line problem between of heterogeneous systems and it is shown rating which is essential ... nl> Energy Management system (EMS) and Database <nt>Number of Transformers</nt> Management System (DMS) applications are based on < ...
Terms matched: 2  -  Score: 9  -  1,437k
Year: 2011, Volume: 11, Number: 4
... value δ max depends on the system load flow mathematical model, the following generator transformer impedance and the network relationships may be written; configuration and normally is found ... consists of 62 buses, condition for the study system when the reactive power 31 transformers, 64 transmission lines, 19 synchronous limits of the system generators are represented ...
Terms matched: 2  -  Score: 5  -  483k
Year: 2011, Volume: 11, Number: 4
... with their attributes. The connectivity model is composed of transformer substations (represented by PowerSystemResource) connected with power ... Large data model Q is a set of the elements transformers, switches, fuses and sections in power system ... calculation made for each region makes previously (ConductingEquipment and PowerTransformer) and nodes mentioned set Y (4) ...
Terms matched: 3  -  Score: 10  -  594k
Year: 2011, Volume: 11, Number: 2
... magnitude is distance between them being 5 mm. An a.c. voltage was explained in terms of the increase of the cavity inner wall applied from the above mentioned transformer. The PD conductivity. The PD behaviour is studied in epoxy resin activity was detected by a typical PD detecting system samples and is explained with the aid ...
Terms matched: 1  -  Score: 7  -  1,121k
Year: 2011, Volume: 11, Number: 2
... SC in a two-winding high frequency stray capacitance between conductor wire filaments. The new transformer for circuit simulation. The approach is useful for proposed method is called vespiary ... self- adjacent wire filaments (WFs) and capacitance between the capacitance of high-voltage transformers is studied in [9]. In wire filaments and central cylindrical liner ...
Terms matched: 2  -  Score: 28  -  1,295k
Year: 2011, Volume: 11, Number: 2
... to leakage inductance of absorbs the leakage inductance voltage spike. Therefore, this forward transformer is absorbed. The flyback transformer converter can be considered as a proper choice ... In this the preceding modes. In this mode magnetizing inductor is mode, both transformers transfer energy to the output. This charged and D 1 is off. ...
Terms matched: 2  -  Score: 41  -  1,350k
Year: 2011, Volume: 11, Number: 2
... 2, 2011 A New Method for Detection and Evaluation of Winding Mechanical Faults in Transformer through Transfer Function Measurements Mehdi BIGDELI1*, Mehdi VAKILIAN2, and Ebrahim RAHIMPOUR3 ... University of Technology, Tehran, Iran 3 ABB AG, Power Products Division, Transformers, Bad Honnef, Germany* Email: m.bigdeli@srbiau.ac.ir 1 Abstract — ...
Terms matched: 2  -  Score: 182  -  823k
Year: 2011, Volume: 11, Number: 2
... The proposed system the input and the output current can be continuous. From the PFC power circuit as shown in Fig.2 an isolation iS L1 C1 C2 L2 iO transformer is used to isolate between load and the AC line. The power converter is designed to operate in a continuous iL1 iL2 vac SW1 D1 vO conduction mode ...
Terms matched: 1  -  Score: 3  -  853k
Result Pages: << Previous 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 Next >>


Search took 0.271 seconds


The search engine database includes all papers published after 2007, including titles, author names, abstracts, keywords, full papers text, references and citations. For papers published between 2001 and 2006, please visit the Archive section.


We invite you to try the most frequently used search terms:

system - power - control - fault - network - load - model - frequency - converter - transformer - harmonic - computer - algorithm - cancer - simulation - computer - estimate - optimal control - expert system - electromagnetic - interference - data transmission - neural network - electrocardiogram signal - model - cluster - design - wavelet - antenna - wireless sensor - coupling - robust - noise - signal processing - system identification - translation - nonlinear systems - induction motor - speed controller - shape optimization - fuzzy network - wireless sensor network


Website loading speed and performance optimization powered by: 


DNS Made Easy